NISSEI CORPORATION E6581815F-6266.20 Operation panel parameter6.20.1 Prohibition of key operations and parameter settings : Parameter write protection selection : Panel frequency setting prohibition (fc) : Local/remote operation prohibition for remote keypad : Panel operation prohibition (RUN key) : Prohibition of panel emergency stop operation : Prohibition of panel reset operation : / change prohibition during operation : Password setting () : Password examination FunctionThese parameters allow you to prohibit or allow operation of the RUN and STOP keys on theoperation panel and the change of parameters. Using these parameters, you can also prohibitvarious key operations. Lock parameters with a password to prevent configuration.[Parameter setting]Title Function Adjustment range Default setting Parameter write protection selection0: Permitted1: Prohibited (Panel andextension panel)2: Prohibited (1 + RS485communication)0 Panel frequency setting prohibition (fc) 0: Permitted, 1: Prohibited 0 Local/remote operation prohibition forremote keypad 0: Permitted, 1: Prohibited 1 Panel operation prohibition (RUN key) 0: Permitted, 1: Prohibited 0 Prohibition of panel emergency stopoperation 0: Permitted, 1: Prohibited 0 Prohibition of panel reset operation 0: Permitted, 1: Prohibited 0 / change prohibitionduring operation 0: Permitted, 1: Prohibited 1 Password setting ()0: Password unset1-99989999: Password set0 Password examination0: Password unset1-99989999: Password set0