NISSEI CORPORATION E6581815L-11212. Specifications12.1 Models and their standard specifications Standard specificationsItem SpecificationInput voltage class 3-phase 240V classApplicable motor (kW) 0.1 0.2 0.4 0.75 1.5 2.2Type VFNC3MForm 2001PY-A30 2002PY-A30 2004PY-A30 2007PY-A30 2015PY-A30 2022PY-A30Capacity (kVA) Note 1) 0.3 0.6 1.0 1.6 2.9 3.9Output current (A)Note 2)0.7(0.7)1.4(1.4)2.4(2.4)4.2(3.6)7.5(7.5)10.0(8.5)Output voltage Default setting Note 3)RatingOverload current rating 150%-60 seconds, 200%-0.5 secondVoltage-frequency 3-phase 200V to 240V - 50/60Hz Note 6)Allowable fluctuation Voltage 170 to 264V Note 4), frequency ±5%Power supplyRequired Power supplycapacity (kVA) Note 5) 0.5 0.8 1.4 2.5 4.3 5.7Protective method (IEC60529) IP20Cooling method Self-cooling Forced air-cooledColor RAL 7016Built-in filter -Note 1. Capacity is calculated at 220V for output voltage.Note 2. Indicates rated output current setting when the PWM carrier frequency (parameter f300) is 4kHz or less. Between 5kHz and 12 kHz, the rated output current is indicated in the ( ). Above 13 kHz, the output current must be reduced.(Refer to section 6.10) The default setting of the PWM carrier frequency is 12kHz.Note 3. Output voltage is default setting.Note 4. 180V-264V when the inverter is used continuously (load of 100%).Note 5. Required power supply capacity varies with the value of the power supply side inverter impedance (including those ofthe input reactor and cables).Note 6. Rated power supply voltage of our IPM Gear Motor standards are 200 to 230V. Please call us for using at 240V.