NISSEI CORPORATION E6581815K-41111.3 Extended parameters Input/output parameters 1Title CommunicationNo. Function UnitMinimumsetting unitPanel/CommunicationAdjustment range DefaultsettingUsersetting Reference 0100 Low-speed signaloutput frequencyHz 0.1/0.01 0.0- 0.0 6.1.1 0101 Speed reachsetting frequencyHz 0.1/0.01 0.0- 0.0 6.1.3 0102 Speed reachdetection bandHz 0.1/.01 0.0- 2.5 6.1.26.1.3 0104 Always activefunction selection 1 - - 0-153 *6 0 6.3.2 0105 Priority selection(Both F and R areON)- - 0: Reverse1: Slowdown Stop1 6.2.1 0108 Always activefunction selection 2- - 0-153 *6 70(SVLOCK)6.3.2 0109 Analog/logic inputSelection(VI terminal)- - 0: Voltage signal input (0-10V)1: Current signal input (4-20mA)2: Logic input3: Voltage signal input (0-5V)0 6.2.26.3.36.4.27.2.17.3 0110 Always activefunction selection 3- - 0-153 *6 6(ST)6.3.2 0111 Input terminalselection 1A (F)- - 2(F) 0112 Input terminalselection 2A (R)- - 4(R) 0113 Input terminalselection 3A (S1)- - 10(SS1) 0114 Input terminalselection 4A (S2)- -0-201 *612(SS2) 0115 Input terminalselection 5 (VI)- - 8-55 *6 14(SS3)6.3.36.4.17.2.1 0127 Sink/sourceswitching- - 0: Sink(Internal power supply),100: Source,200: Sink(External power supply)1-99, 101-199, 201-255: invalid0 6.3.1 0130 Output terminalselection 1A (OUT)- - 68(Break)6.3.47.2.2 0131 Output terminalselection 2A (FM)- - 6(RCH) 0132 Output terminalselection 3 (FL)- - 10(FL) 0137 Output terminalselection 1B(OUT)- - 255(alwaysON) 0138 Output terminalselection 2B (FM)- -0-255 *7255(alwaysON)0: and and 1: or and 2: and or 0139 Output terminallogic selection(OUT, FM)- -3: or or 0*6: Refer to section 11.4 for details about input terminal function.*7: Refer to section 11.5 for details about output terminal function.