NISSEI CORPORATION E6581815F-466.2 Input signal selection6.2.1 Priority selection (Both F and R are ON) : Priority selection (Both F and R are ON) FunctionThis parameter allows you to select the direction in which the motor runs when a forward run (F)command and a reverse run (R) command are entered simultaneously.1) Reverse2) Slowdown stop[Parameter setting]Title Function Adjustment range Default setting Priority selection (Both F and R areON)0: Reverse1: Slowdown stop 1Output frequency attainment signalForward run command - ONOFF + ONOFF0Output frequency [Hz]Time [s]