Service Manual ALS/XLS 20x/256/27202/2019 | 01 209 Electronics DescriptionSignals for PLC connectionRequired setting: SIGNAL INTERFACE > Interface mode = „PLC signals“.[159] Pin assignment D-Sub15 connector[160] Pin assignment M12 socket (fem. connector; output signals). Matching connector: article no. A8144.[161] Pin assignment M12 socket (male connector; input signals). Matching connector: article no. A8145.Signal name FunctionInhibit InputIf the signal is active, start signals at both signal interfaces (standard and AI) areignored. Triggering via -button is possible.AI installed: alternatively, the Inhibit input at the AI can be activated (SIGNAL IN-TERFACE >ACTIVE INPUTS > Inhibit signal = „Opt. appl.interf“)Warning In InputAn external warning status can be signaled by OR-link at the warning outputError In InputAn external error status can be signaled by OR-link at the error outputReady OutputActive in dispensing mode (online or online settings)Not active in configuration mode (offline inclusive error status) and in tandemmode at the deactivated machineIout < 500 mA 1)123456789101112131415ErrorReadyDispense EndWarning GNDGNDGNDGND+24 VError In AWarning In AInhibit AError In KWarning In KInhibit KReady 4GND 3Error 28 Warning5 GND6 Dispense End1 GND7 GNDError In A 6GND 7Inhibit K 18 +24 V5 Error In K4 Warning In A2 Inhibit A3 Warning In K