Service Manual ALS/XLS 20x/256/27202/2019 | 01 210 Electronics Description1) I max over all outputs < 1500 mASignal response „Dispense End“[162] Signal response of „Dispense End“.The signal „Dispense End“ can be controlled by the functions in the SIGNAL INTERFACE >PLC SIGNALSsubmenu.A Duration of the dispensing operation [162A]B Period setable via SIGNAL INTERFACE >PLC SIGNALS > Disp.end delay [162B]C Period setable via SIGNAL INTERFACE >PLC SIGNALS > End pulse width [162C]D Signal modes; setable via SIGNAL INTERFACE >PLC SIGNALS > End dispense mod [162D]– Modes high/low active: The signal is activated with the start of dispensing. The duration is thesum of the three periods A+B+C.– Modes high/low pulse: The signal is activated after dispensing ended and after period B and itlasts period C [162C].Error OutputSignal active when an error message appears on the operator panel displayIout < 500 mA 1)Dispense End OutputSignal that can be used to activate a secondary unit (e.g. a printing unit). Signallength and delay can be set via the function menuIout < 500 mA 1)Warning OutputActive, if a warning status occurs (e. g. label roll diameter below desired nominalvalue)Iout < 500 mA 1)Signal name Functiondispensehigh activelow activehigh pulselow pulseDB CA