Service Manual ALS/XLS 20x/256/27202/2019 | 02 94End pulse width function– Sets the duration of the „Dispense End“ signal.– Setting range: [0…10000] ms.Submenu >APPLIC. SIGNALSOnly appears, if SIGNAL INTERFACE > Interface mode = „Applic. signals“.Applicator type function– If an applicator is used to attach the labels, the applicator type is set here. Alternatively, “DirectDispense” should be selected to dispense without an applicator.– Settings: [„LTP - LTPV“, PEP, „PEP Blow on“, „PEP II Sensor“, ASA, „Reverse PEP“, „DirectDispense“, „BTS“, „O-ring applicat.“, „LA-BO“, „LA-TO Timed“, „LA-TO Sensor“, „LA-TO BO Ti-med“, „LA-TO BO Sensor“]“LTP - LTPV”: Sensor controlled tamp-on applicator. The movement of the pneumatic cylinderis limited by (touchdown-)sensors, which react to slight pressure onto the product. The LTPVadditionally sucks the labels on with a vacuum nozzle.PEP: The cylinder movement is limited by a setable length of time. After the run out of this ap-plication time, the applicator moves back into home position“PEP Blow on”: PEP-type applicator with blow on function: After run out of the application time,the blow on function is activated. After run out of the blow on time, the applicator moves backinto home position“PEP II Sensor”: The cylinder movement is limited by a (touchdown-) sensor, which signals thecontact to the product and triggers the backwards-movement.ASA: Vintage applicator. Same function as LA-BO.“Reverse PEP”: Combined tamp-on/blow-on applicator. The applicator moves to its end positionand “waits“ for the start signal. The start signal triggers the blow on valve which is active for thedefined blow on time. After the run out or the blown on time, the applicator moves to home po-sition, gets the next label and moves to the wait position.“Direct Dispense” Labelling without an applicator“BTS”: Setting for operation with Bad Tag Separator, an additional unit that removes “bad” RFIDlabels before they are dispensed.“O-ring applicat.”: Vintage applicator.LA-BO: Blow-on applicator. The label is moved by airstream over a short distance onto the prod-uct.„LA-TO Timed“: Setting for a time-controlled LA-TO. Same function as PEP.„LA-TO Sensor“: Sensor-controlled tamp-on applicator.„LA-TO BO Timed“: Setting for time-controlled LA-TO BO.„LA-TO BO Sensor“: Setting for sensor-controlled LA-TO BO.For information about the signal wave forms see chapter Signal wave forms of applicatorsignals on page 200.For information about the applicator function refer to the relevant applicator service manual.