OKIFAX 5700/5900 2 - 372.9.2.3 Technical Functions (Setup)• Table 2.9.2.3 shows the initial setting items and their purpose. (The default setting isdifferent by the individual countries.)• Each item can be accessed by entering it on Technical Setup.• The detailed procedures of the initial setting items will be explained on the followingtables.Table 2.9.2.3 Technical Functions: Setup (1/11)No. Item Specifications01 Service bit02 Monitor control03 Country codeEnables the serviceman to make special settings.If this setting is OFF, some settings and report printfunction may become unavailable.1) Setting valuesON: Enables the serviceman to make settings.OFF: Disables the serviceman to make settings.Sets up the line monitor.If this setting is OFF at the time of transmission, the lineis monitored during dialing but the line will not be moni-tored after a specified time lapse (about 5 sec).If this setting is ON, the line will be monitored till the endof communication.1) Setting valuesON: Monitored continuouslyOFF: Not monitored continuously* The tone level can be adjusted by setting MonitorVolume.Set a country code.1) Setting valuesSelect a country code:USA/INT/GBR/IRL/NOR/SWE/FIN/DEN/GER/HUN/TCH/POL/SUI/AUT/BEL/HOL/FRE/ POR/ESP/ITA/GRE/AUS/NZL/SIN/HNG/LTA/MEX* The setting data must be transferred to the G4board.* Setup a dial parameter when changing a countrycode.* Distinctive ring sets to OFF.* In case Country code is changed in FRE:Forcibily, set to 7dB when the attenuator settingvalues are set between 0dB to 6dB.