OKIFAX 5700/5900 1 - 11No. Item Specifications1 Applicable line2 Line interface1) Impedance2) Sending power level3) Receiving power level3 Type of document to be transmit-ted1) Width2) Length3) Thickness4) Shape5) Opacity4 Effective reading width1) PSTN (Public switched telephone network)2) PBX (Private branch exchange )3) ISDN (Integrated services digital network): Option4) LAN (Local area network): Option600 ohm balancedNote: Impedance may differ by the requirement of PTT0 dBm to -15 dBm range(Adjustable in 1 dB steps: Technical Setup No.21)0 dBm to -43 dBm(In case of V.34 TX/RX, -3 ~ -36 dBm)Max. 216 mm (NA Letter)Min. 148 mm (ISO A5)Note: Effective reading width is NA Letter (215.4 mm)Min. 128 mm (5 inch)Max. 356 mm (14 inch)Long document detection: 380 mm or 1500 mm(Technical Setup No. 10: To enables or disables the longdocument scanning.)Based on common bond paper,1) 0.08 to 0.13 mm for multiple page feeding2) 0.06 to 0.15 mm for single page feedingRectangularDocument allowing less than 40% of the scanner sourcelight to pass through them.Note (*1): Printing width will be 206 mm.Document WidthNA Letter (216 mm)US/CANADAISO A4 (210 mm)INT’LCommunicationmode/paper width Effective reading widthCopy sizeG3/A4G3/A4LetterA4215.4 mm for TX211.3 mm for local copy208.6 mm for TX211.3 mm for local copy (*1)1.5 Basic Performance SpecificationsTable 1.5.1 shows basic performance specifications:Table 1.5.1 Basic Performance Specifications