Installation 2 - 43 OKIFAX 5300/5600Service Manual, P/N 59278301Technical Functions 24 to 27 (Table 2.9.2)T.F.No. Name of Function The Display Shows24 MF attenuator26 CML timing27 Head strobe24:MF ATT[ X ] YES(←) NO(→)27:HEAD STROBE[ X ] YES(←) NO(→)→SettingX:0 DB → 1 DB →2 DB → • • • • • → 15 DB → 0 DB → ••••25:RING DURA. *10 MS[ X ] YES(←) NO(→) To 26: CML TIMINGX: 10 - 99→RING DURA. *10 MS[10] ENTER 2DIGITS24:RING DURA. *10 MS[11] YES(←) NO(→)2-digit timer entered.→→(Example)25 Ring duration detection time26:CML TIMING *100MS[ X ] YES(←) NO(→) To 27: HEADSTROBEX: 01 - 19→CML TIMING *100MS[01] ENTER 2DIGITS26:CML TIMING *100MS[03] YES(←) NO(→)2-digit timer entered.→→(Example)To 28: HEADWIDTHX:5digits (0/1)→→27: HEAD STROBE[01100] ENTER 0/126:CML TIMING *100MS[01101]YES(←) NO(→)0/1 entered.→(Example)