T.F.No. Item Specifications DefaultInstallation 2 - 28 OKIFAX 5300/5600Service Manual, P/N 59278301This table shows the initial setting items and their purposes. The default settings may differ by country.Each item can be accessed by entering the corresponding service number on Technical Function.Note 1:S-ON: Effective if the service bit has been set to ON.FP: Function program settingTF: Technical function settingOFF28.8059 sec.035 sec130 secSwitches the function of limiting image compres-sion only to the MH codes.This affects all communications, and should onlybe used as a last resort.ON : Coding scheme is MH only. When thereceiving image data is affected bynoise on the telephone line.OFF : Any of MH, MR and MMR.Specifies the modem’s starting speed, 33.6K,28.8K, 14.4k, 9.6k, or 4.8kbps.Note: The following protocol is added toOKIFAX 5600:ITU-T standard V.34 for 33.6K or 28.8kbps operation.Registers the time duration (in seconds) forwhich the fax waits for the remote station’sanswer.This timer starts when the last dialled digit hasbeen sent in the automatic transmission mode.* Selects the 3 digit timer010 to 255 sec (in one second steps)T1 (RX), timeout value (later)Registers the time duration (in seconds) for which thefax waits for the remote station’s answer. This timerstarts after the DIS is transmitted, and checked thistimer by the transmission timing signal. If T1 times out,the fax disconnects the line.* Selects the 3 digit timer010 to 255 sec (in one second steps)T2, timeout value (layer)Registers the time duration (in seconds) for which thefax detects the EOL interval during reception of phaseC. The fax disconnects the line when EOL can notdetect within T2 timer.* Selects the 3 digit timer001 to 255 selectable. (in 100ms steps)For example: 060 x 100 ms =6 s13 MH only14 High-speed modem rate15 T1 (TX), timeout value16 T1 (RX), timeout value17 T2, timeout value