– 106 –Error messagesWhen a warning occurs in this unit, the warning lamp lights up.Opening the DIAG menu will display the warning description on the counter display and themonitor. Also, when an abnormal operation is detected in this unit, the AUTO OFF lamp lightsup and a message appears on the counter display.DIAG menu This display the VTR information.VTR information includes “WARNING” information and “HOURS METER” (usage time)information. A DIAG menu appears on the monitor when the monitor is connected to theVIDEO OUT3 connector on the connector section.Displaying the DIAG menu1 Press the DIAG button.The DIAG menu screen is displayed on the monitor.2 The “WARNING” information and “HOURS METER” information can be switched bypressing the search buttons.3 Press the DIAG button again to return to the original display.“WARNING” information display• A warning message is displayed whenever a warning occurs (the warning lamp lights up).When warnings have not been detected, “NO WARNING” is displayed.• When multiple warning occur, the descriptions for each warning can be checked by turningthe search dial.CH CONDITION ENTER ESCAPE SHIFTONAUDIO CH SELECT SHIFT ADJTC SET STARTTC/CTLRESETTC INTTCTAPEUBSTAND BYEDIT PLAYREW STOPSERVORECFFREC INHIBITPLAYEREXT EEMODEREMOTE PUSHREV FWDRECORDERLOCALCONTROLCH 11ASMBLPREVIEWREVIEW AUTO EDIT PREROLLSET UP PROG 1 2 3MENU SAVE/ PROG MENU MENU SET DIAGEXITTRIMAININ SET OUTAOUTMULTICUE INSERTVIDEO CH1/5 CH2/8 CH3/7 CH4/8 CUE TCCH 4OFFPOWERMETERFULL/FINEMONITOR SELECTLEVELHEADPHONESCH 1/5 CH 2/6 CH 3/7 CH 4/8 CUERECLRPBPULL FOR VARIABLEPULLOPENPULLOPENCH 5 CH 82 3 4 5 6 7 8JOG SHTLSLOWEJECTM-cassette / ADAPTERCaution: Do not insert S-cassette without adapterSTATUS STATUS 1 2 3 421, 3MODE/SEL EXIT