– 107 –Displaying the “HOURS METER” informationTurn the search dial to move the cursor ( * ). The description for the item where the cursor is located is shown as asuperimposed display.Item No. Item DescriptionH00 OPERATIONH01 DRUM RUNH02 TAPE RUNH03 THREADINGH11 DRUM RUN rH12 TAPE RUN rH13 THREADING rH30 POWER ON• The resettable items in the “HOURS METER” information are reset by the shop when performing maintenance orother work.• The search buttons and the search dial cannot be operated while the DIAG menu is displayed.If “T&S&M” is selected in the setup menu No. 006 (DISPLAY SEL), a message appears in the mode displaywhenever a warning or error occurs. When multiple events occur, the event with the highest priority is displayed.Priority Display DescriptionHigh Error messages(See error message table)INT SGNO INPUTWarning messages(See warning messageLow table)Warning messagesPriority Monitor display Description VTR operationHigh FAN STOP Operation continuesNO RFOperation continuesSERVO NOTLOCKED Operation continuesLOW RFOperation continuesHIGH ERROR Operation continuesLow RATEError messagesDisplays the time that the power has been supplied in one-hour units.Displays the time that the drum has been rotating in one-hour units.Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG,VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) inone-hour units.The number of times for threading/unthreading is displayed in single units.Displays the time that the drum has been rotating in one-hour units. (Can be reset)Displays the time that the tape has been running during FF, REW, PLAY, SEARCH (JOG,VAR, SHTL), REC, and EDIT modes (except for STILL in the JOG, VAR or SHTL mode) inone-hour units. (Can be reset)The number of times for threading/unthreading is displayed in single units. (Can be reset)The number of times the power has been turned on is displayed in single units.When an abnormal operation is detected in this unit, the AUTO OFF lamp lights upand an error message is displayed.When INT SG is selected in setup menu No.600 (VIDEO IN SEL) or No.700(AUDIO IN SEL), pressing REC button or EDIT button causes the display to begiven for 2 sec. from the beginning (EE mode).Similarly in edit mode, the display will be given for 2 sec. from the beginning.In case of no input signal at the connector selected by setup menu No.600 (VIDEO IN SEL)or No.700 (AUDIO IN SEL) except analog audio, pressing REC button or EDIT buttoncauses the display to be given for 2 sec. from the beginning (EE mode).Similarly in edit mode, the display will be given for 2 sec. from the beginning.When a warning occurs in this unit, the warning lamp lights up and a warningmessage is displayed. When multiple warnings occur, the warning with the highestpriority is displayed.This is displayed when the fan motor stops.This appears when a blank part of the tape lasting for 1 or moreseconds has been detected during playback.When all the following conditions have been met, it will be recognizedas a blank part.· When no signals are output from any of the heads· When the playback data cannot be read· When CTL is not presentThis is displayed when the servo is not locked for three or moreseconds during playback, recording, or editing.This is displayed when envelope levels approximately 1/3 that ofnormal levels are detected for more than one second duringplayback, recording, or editing.This is displayed when the error rate increases and correction/interpolation is performed on either the video or audio playback signal.