– 59 –ERROR LOG functionERROR LOG mode selectionIn status with MODE/SEL button g pressed, ERROR LOG mode can beselected.When EXIT button h is pressed, ERROR LOG mode is canceled and changed to normal mode.Outline In case the following warning message is given during tape running, the time code and operation modeas well as the warning message will be stored, which can be read in the form of a list at VTR statusdisplay 3.It is possible to store up to 99 warnings. Also, in case of more than 99 warnings, it will be processedaccording to the setting of setup menu No. 015 (AUTO STEP).Setup menu No.015 (AUTO STEP) (Default setting is OFF)In ERROR LOG function, warning can be stored up to 99 messages. If it exceeds the capacity,processing mode will be selected for storage.OFF: Upper limit is 99 messages. Warning messages generated after that are not stored.ON : 99 messages are stored. Warning messages given after that are stored in the place of 99thmessage. Warning messages already stored are then shifted down in the direction of smallernumbers in order.• The image of storage with it set to ON is illustrated below.Warning message to be storedNO RFSV NOT LOCKEDLOW RFHIGH ERROR RATEDescriptionBlank portion of tape was detected more than 1 sec. (Normal playbackmode)Servo was unlocked for over 3 sec. (Record/Normal playback/Edit mode)Envelop level detected was about 1/3 of the normal level for over 1 sec.(Record/Normal playback/Edit mode)Error rate worsened, and video or audio playback signal was subjected tocorrection/calibration. (Normal playback mode)Store No.1/992/99::99/99Warning storedWarning 1Warning 2::Warning 99Store No.1/992/99::99/99Warning storedWarning 2Warning 3::Warning 100Stored up to 99messages, and100th messagewas given.