27 (S)ConnectionsChanging the IP address on the unit to match the IPaddress of the remote camera or switcher[Remote camera settings]The unit sets the IP addresses for the remote camerasthat have been detected by associating them with cameranumbers whose connection setting is set to “NoAsign”.Connection settings:On the [SYSTEM] menu, select [CAMERA CTL], andthen display items [CAM1] to [CAM100].Setting or changing IP addresses:On the [SYSTEM] menu, select [CAM IP ADR], andthen display items [CAM1] to [CAM100].Example: Three remote cameras are in operation. An additional remote camera with an IP addressof “192.168.000.020” is newly introduced (andbecomes remote camera E). Remote camera E is detected. In [CAMERA CTL], the [CAM4] item is set to“NoAsign”.In the above example, on the [SYSTEM] menu, in[CAM IP ADR], the IP address of the [CAM4] item isset to “192.168.000.020”. Subnet mask, default gateway, and port numbersettings are the same as those for the unit.[Switcher settings]On the [SYSTEM] menu, in [SW CTL], if the [SW] itemis set to “NoAsign”, the IP address for the switcher willbe set in the [IP:SW] item from [SW IP ADR] on the[SYSTEM] menu.If different subnet mask settings are used for unit andremote camera, no operations using the network will bepossible.Note1 Connect the additional remote cameras andthe switcher to be introduced and the unit tothe network within the same subnet.2 On the [SYSTEM] menu, select [AUTO SETIP], and display [AUTO SETUP]. Then select“KEEP”, and press the F2 dial.1.AUTO SETUPKEEPBoth the number of devices (all remote cameras and theswitcher) currently being managed by the unit and thenumber of new devices detected are displayed on theLCD panel.C:1/4 S:0/1YESC:1/4Number of devices currently managed by theunit + Number of new devices detectedNumber of new devices detectedC: Remote camera, S: Switcher Memo If the number of new devices detected exceedsthe number of devices that can be registered(100 remote cameras and 1 switcher), [C/S OVER!]will be displayed at the bottom of the LCD panel.Automatic IP address setting can be performed evenin this state, but IP addresses will be set only for thenumber of devices that can be registered.C:20/100 S:1/1C/S OVER! YES The number displayed for “Number of new devicesdetected” may be lower than the actual number ofdevices to be set, due to a cause such as the remotecameras or switches not being powered on. In thiscase, eliminate the cause of the problem, select“RETRY”, and then press the F2 dial to retry theoperation.The number of units to be added can be updated.C:20/20 S:1/1RETRY