161Maintenance and Inspections: Warning SystemMaintenance and Inspections6. Recording ErrorDisplay windowindication“00:00:00:11” appears in the time codedisplay field. Even after recording isstopped, this display continues to blinkuntil the next operation is performed.WARNING lamp Blinks 4 times per second while recordingcontinues.Tally lamp Blinks 4 times per second while recordingcontinues.Viewfinder The “REC WARNING” indicator lights up.Warning tone Beeps 4 times per second while recordingcontinues.Warning descriptionThis indicates a failure either in the P2card recording or the recording circuit.This is displayed when attempting torecord clips where the total quantityexceeds the upper limit (1000 pieces) fora single P2 card.Recording/playbackoperation The recording may stop or continue.CountermeasuresConfirm the recording/playback operationafter turning off the power supply onceand then turning it on again.If the recording cannot be performednormally, change the P2 card.7. Low Wireless Signal ReceptionDisplay windowindication No display.WARNING lamp Blinks 4 times per second (during pauseand recording).Tally lamp Blinks 4 times per second while recordingcontinues.Viewfinder The “WIRELESS-RF” indicator lights upwhile recording continues.Warning tone Beeps 4 times per second while recordingcontinues.Warning description This error indicates poor wireless audioreception conditions.Recording/playbackoperationContinues to operate without receivingthe wireless microphone signal.CountermeasuresCheck the microphone power supply andthe reception status of the wirelessreceiver.8. Battery Nearly EmptyDisplay windowindicationOne of the bars in the battery remainingindicator starts blinking.WARNING lamp Blinks once per second.Tally lamp Blinks once per second.Viewfinder The “BATT” LED blinks.Warning tone Beeps 4 times per second.Warning description The battery is about to run out.Recording/playbackoperation Continues to operate.Countermeasures Replace the battery as required.9. P2 Card Nearly FullDisplay windowindicationOne of the bars for remaining MEDIAcapacity starts blinking.WARNING lamp Blinks once per second while recordingcontinues.Tally lamp Blinks once per second while recordingcontinues.Viewfinder The P2 card remaining capacity indicatorblinks.Warning tone Beeps once per second while recordingcontinues.Warning description The total remaining capacity of all the P2cards is 2 minutes or less.Recording/playbackoperation Continues to operate.Countermeasures Replace the cards. If there is an emptycard slot, insert a new card.10. P2 Card ErrorDisplay windowindicationIf the error occurs during recording,“00:00:00:11” appears in the time codedisplay field. The indication continues toflash after recording is stopped and untilthe next operation is performed. There isno indication if the error occurs duringplayback.WARNING lampIf the error occurs during recording, thelamp flashes 4 times per second for aperiod of about 3 seconds after recordingstops. The lamp does not light if the erroroccurs during playback.Tally lampIf the error occurs during recording, thelamp flashes 4 times per second for aperiod of about 3 seconds after recordingstops. The lamp does not light if the erroroccurs during playback.ViewfinderA flashing “CARD ERR ½” appears. Inthe actual indication the ½ is replaced bythe slot number of the P2 card thattriggered the error.Warning toneIf the error occurs during recording, thetone sounds 4 times per second for aperiod of about 3 seconds after recordingstops. The tone does not sound if theerror occurs during playback.Warning description An error has occurred while recordingdata to or playing data from a P2 card.Recording/playbackoperation Stop recording or playback.Countermeasures Replace the affected P2 card.