NetworkENGLISH - 77 SettingsError information pageJIf [Error (Detail)] is displayed in the self-diagnosis information display column on the [Projector status] screen,click the part to display the details of the error.Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.•When [FAILED] has appeared for an itemParameter DescriptionMAIN CPU BUS Trouble has occurred in the microcomputer circuitry. Consult your dealer.FAN Trouble has occurred in the fan or its drive circuit. Consult your dealer.INTAKE AIR TEMPERATUREIntake air temperature is high. It could be because it is used in an environment of hightemperature such as close to a heating device, etc., the air intake is blocked, or the airfilter is clogged.AROUND LAMP TEMPERATURE The temperature around the lamp is too high. Exhaust may be blocked, or [Fan control]mode may be set wrong. See [Fan control] of the Functional Manual. (Æpage 65)OPTICS MODULE TEMPERATURE Optics module temperature is high. The exhaust air port maybe blocked or the air filteris clogged.LAMP REMAIN TIME The lamp runtime has exceeded the prescribed cumulative time, and it is now time toreplace the lamp.LAMP STATUS The lamp has failed to light.Wait a short while for the lamp to cool off, and then turn on the power.APERTURE(CONTRAST-SHUTTER) Trouble has occurred in the contrast shutter circuitry. Consult your dealer.SHUTTER There is a problem with shutter.AIR FILTER There is a problem with the air filter unit.FILTER UNIT The air filter unit is not installed.Network status pageJDisplays the current configuration information of the network.Displays the configuration details of wired LAN.OK: Normal operationFAILED : Occurrence of troubleWARNING: Warning