9 © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49VConnecting / Setting Procedures2-3-2 When Using in Combination with Application Expansion Unit SF-C14EX1. Set the SF4B / SF4B series andSF-C14EX, and check that the SF4B /SF4B series works properly. Formounting method of SF4B / SF4Bseries or SF-C14EX, refer to the respectiveInstruction Manuals.2. Turn OFF the power, and disconnect the ex-tension cable with connectors connected tothe emitter side (or receiver side) of SF4B/ SF4B series from SF-C14EX, andthen connect the emitter side (or receiverside) of this device to the receiver side (oremitter side) connector of SF-C14EX.FUNCTION㧙CANCELENTER㧗Bottom capcableSF4B / SF4B series(Emitter or receiver)SF-C14EXSF4B / SF4B series(Receiver or emitter)This device3. Turn ON the power, and set the function with this device.After the power of this device is ON, a total approx. 30 sec. will be taken for data transmission withSF4B / SF4B series and SF-C14EX. While data transmission, “ ” lights up in revolving.[The safety output 1 / 2 of SF-C14EX series are set to “OFF” while this device has been connected.]REFERENCE Refer to “3-2 Functional Descriptions Expansion Unit SF-C14EX>” for the details of the functions, and refer to “3-3 FunctionSetting (Operation Procedure)” for the setting procedures of the functions respectively.4. Turn OFF the power, and remove this device.5. Connect the SF4B / SF4B series and SF-C14EX, and return the device to the state de-scribed in procedure 1.6. Check that the SF4B / SF4B series works as set at the procedure 3.Then, inspect the SF4B / SF4B series.REFERENCE Refer to “Chapter 4 Maintenance” of the SF4B / SF4B series instruction manual forthe details of the inspection of the SF4B / SF4B series.Bottom capcableSF4B / SF4BseriesExtension cablewith connectorsSF-C14EX