30© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49VFunction Setting3-3-5 Copy Function“****” indicates the connection stateof the system. “ ”: SF4B / SF4B se-ries is used only. “ ”: SF-C14EX is used incombination.*1: The setting of the relay monitoris as follows.When set to ineffective: CLRWhen set to effective: Set time(100 to 600ms, in units of 10ms)*2: The override function can be setin the range of 60 to 600 sec. (inunits of 10 sec.)Notes: 1) The indication is on the main sensor(CH1) only.2) When using in combination withSF-C14EX, it is not indicated.key operation: FUNCTION: ENTER: CANCEL: -: +(Override)*2(Note 1, 2) (Note 1)Muting sensoroutput operationsettingMuting lampdiagnosisfunction setting5. Copy function Select function(Upload)(Download)(Monitor)Select sensorInputpasswordCheck function6. To Muting settingchanging function(Error)To 5OKNGReceive(Error)To 5OKNGReceiveConfirm functionof system deviceSelect item(Note 1)(Note 1)(Note 2)(Note 1)(Note 2)(Note 1)(Note 2)Detail display(Only for SET)(Effective)(Ineffective)Keep pressing switch OKDetail display(Only for SET)(Effective)(Ineffective)Keep pressing switch OKDetail display(Only for SET)(Set beam channels)Both ends beamchannel ineffec-tive settingNon-serialbeam channelsetting(Emission intensity control)(Input mode)(Interlock)(Relay monitor) *1(Protection)(Auxiliary output)Fixed blanking effective/ ineffective displayFloating blanking effective/ ineffective display