16© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49VFunctional Descriptions3-1-9 Protective FunctionThe functional settings are not allowed to change without the input of a password.When the protective function is set to “effective,” the setting can be changed by inputting the password.The setting contents monitor function can be used regardless of the protective function “effective / ineffective.”The password should be a 4-digit number from 0 to 9. (The password of the factory setting is “0000.”)The protective function is set on the receiver side.3-1-10 Initialization FunctionThe settings can be initialized. (factory setting) (Note)The factory setting of each function is as follows.Function SettingFixed blanking function IneffectiveFloating blanking function IneffectiveAuxiliary output switching function Mode 0Emission intensity control function Normal modeMuting settingchanging func-tionSetting of the muting function on each beam channel Effective for all beam channelsMuting input conditions A = BSetting of the muting lamp diagnosis function (Ver. 2 or later) EffectiveMuting sensor output operation setting (Ver. 2.1 only) NONOInterlock setting changing function Start / RestartExternal devise monitor setting changing function Effective / 300msOverride setting changing function (Ver. 2.1 only) 60 sec.Note: The setting of the protective function and the setting data of the copy function are not initialized.3-1-11 Setting Contents Monitoring FunctionEach setting of the SF4B / SF4B series can be monitored. The following can be monitored. Model No. / the number of beam channels & * & { & $ Y & = & & { & $ Y Setting of the auxiliary output switching function Setting of the emission intensity control function Setting of the muting setting changing function(Reading out the record of the latest 5 times is possible, however, only for setting beam channel.) Setting of the interlock setting changing function Setting of the external device monitor setting changing function Override setting changing function3-1-12 Override Setting Changing Function (Ver. 2.1 only)Maximum continuous effective time set at the override function can be changed.The maximum continuous effective time can be set in the range of 60 to 600 sec. (in units of 10 sec.).The factory setting is 60 sec. When the protecting function is set to “ineffective,” the third person may change the set-ting. It is recommended that the protecting function should be set to “effective” so as notto change the setting by the third person. ~ & ; @ % & ; +please contact us.