15 © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49VFunctional DescriptionsMuting input conditions The order for inputting the muting input A and B, which the muting function activates, can be set.Z " " $ Z " %; Z$ Z " %; $ Note: The setting is possible for each channel.Setting of the muting lamp diagnosis function (Ver. 2 or later) The muting lamp diagnosis function can be set to “effective / ineffective.” (Note)The factory setting of this function is effective.ON : The muting lamp diagnosis function is effective.OFF : The muting lamp diagnosis function is ineffective.Note: If the muting lamp diagnosis function is set to ineffective, the muting function is maintained even if the lamp blew.Muting sensor output operation setting (Ver. 2.1 only) Output operation of the muting sensor can be selected.The factory setting is NONO (Normally Open, Normally Open)._ NONO (Normally Open, Normally Open)A muting sensor which is to be connected to the muting input A (ON with light non-received sta-tus, ON with object approaching status and ON with object contacted status)A muting sensor which is to be connected to the muting input B (ON with light non-received sta-tus, ON with object approaching status and ON with object contacted status)_ NONC (Normally Open, Normally Closed)A muting sensor which is to be connected to the muting input A (ON with light non-received sta-tus, ON with object approaching status and ON with object contacted status)A muting sensor which is to be connected to the muting input B (ON with light received status,ON with object non-approaching status and ON with object non-contacted status)3-1-7 Interlock Setting Changing FunctionOne condition can be selected from the following three interlock conditions. It can be set to invalid,too. (Mode 3)_ Start / Restart interlock (Mode 0)The SF4B / SF4B series goes into interlock condition after the power is ON and when it isin the light receiving condition.The factory setting is Start / Restart interlock._ Start interlock (Mode 1)The SF4B / SF4B series goes into interlock condition only when the power is ON. Oncethe SF4B / SF4B series is reset, it does not go into interlock condition again._ Restart interlock (Mode 2)The SF4B / SF4B series does not go into the interlock condition when the power is ON.The SF4B / SF4B series goes into interlock condition only when the SF4B / SF4Bseries receives the light, after the power is ON, the control output (OSSD 1 / 2) is turned intoON once and then the SF4B / SF4B series is blocked.3-1-8 External Device Monitor Setting Changing FunctionThe setting of the external device monitor can be changed.1. Allowable period of the response time: 100 to 600ms (unit of 10ms)The factory setting is 300ms.2. “Effective / ineffective” of the external device monitor function can be selected.The factory setting is “effective.”