28© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49VFunction Setting3-3-3 Auxiliary Output Switching Function*: When two or more SF4B / SF4B series are connected, cancel the protective function of allSF4B / SF4B series.Mode 0: Negative logic of the control output (OSSD 1 / 2) (factory setting)Mode 1: Positive logic of the control output (OSSD 1 / 2)Mode 2: ON during emission, OFF when emission is not done.Mode 3: OFF during emission, ON when emission is not done.Mode 4: OFF when the received light level is unstable (Note 1)Mode 5: ON when the received light level is unstable (Note 1)Mode 6: ON during mutingMode 7: OFF during mutingMode 8: ON in the light receiving conditionMode 9: OFF in the light receiving condition Y~ ; * & + = & & $ & &&&-tion is used.2) When using with SF4B / SF4B series only, if the external device monitor function is not used, set the monitor set-ting to ineffective in “3-3-8 External Device Monitor Setting Changing Function.”(Mode 9)4. To Emission intensitycontrol functionSelect output(Mode 0)(Mode 1)(Mode 2)Send(Error)To 3OKNGInput pass-word (*)3. Auxiliary outputswitching functionkey operation: FUNCTION: ENTER: CANCEL: -: +