7 © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49VConnecting / Setting Procedures2-3 Connecting / Setting ProceduresThis section describes the connecting / setting procedures for both this device and SF4B /SF4B series or SF-C14EX.2-3-1 When Using with Light Curtain SF4B / SF4B Series Only1. Set the SF4B / SF4B series, andcheck that the SF4B / SF4B seriesworks properly. For mounting method ofSF4B / SF4B series, refer to the re-spective Instruction Manuals.2. Turn OFF the power, and disconnect the ex-tension cable with connectors connected toSF4B / SF4B series, and then connectthis device between SF4B / SF4B se-ries (emitter or receiver) and the extensioncable with connectors.Bottom capcableSF4B / SF4BseriesExtension cablewith connectorsTo power supplyFUNCTION㧙CANCELENTER㧗Bottom capcableSF4B / SF4B series(Emitter or receiver)Extension cablewith connectorsTo power supplyThis device3. Turn ON the power, and set the function with this device.After the power of this device is ON, approx. 30 sec. will be taken for data transmission with SF4B/ SF4B series. While data transmission, “ ” lights up in revolving.The control output (OSSD 1 / 2) of SF4B / SF4B series is set to “OFF” while this devicehas been connected.REFERENCE Refer to “3-1 Functional Descriptions SF4B Series Only>” for the details of the functions, and refer to “3-3 Function Set-ting (Operation Procedure)” for the setting procedures of the functions respectively.4. Turn OFF the power, then remove this device.5. Connect both SF4B / SF4B series and the extension cable with connectors and return thedevice to the state described in procedure 1.6. Check that the SF4B / SF4B series works as set at the procedure 3.Then, inspect the SF4B / SF4B series.REFERENCE Refer to “Chapter 4 Maintenance” of the SF4B / SF4B series instruction manual forthe details of the inspection of the SF4B / SF4B series.