20Wiring4 to 20mAC B A 1 2 3 4 5 6 7 8 9 10 11COM NC NO+-VR0 to 5V0 to 10VStart/stopForward/reverse SW1 SW3SW2- +Analogoutput(0 to 5V)ECOpen collectoroutputRelay output+- 200Ω♦ Terminal specifications: "Screw size: M3 (minus screw)""Tightening torque: 0.5 to 0.6N·m"♦ Frequency setting potentiometer (VR) specifications: "10kΩ, 1/4W or morepotentiometer"♦ Relay output contact specifications: 1c no-voltage contact, 250VAC, 0.5A(resistance load)♦ Open collector output specifications: Maximum rating 50VDC, 50mANote 1) When using a 4 to 20mA signal for the frequency setting, alwaysconnect a 200Ω, 1/4W resistor. (The inverter could be damaged ifthe resistor is not connected.)Note 2) Always read each function explanation for the parameters related toeach terminal before starting use.TerminalNo. Terminal function Related parameter No.1 Frequency setting potentiometer connection terminal (+5V) P092 Frequency setting analog signal input terminal P093 Common terminal for 1 , 2 , 4 to 9 signals4 Multi-function analog signal output terminal (0 to 5V/PWM) P58, P595 Start/stop, forward run signal input terminal P086 Forward/reverse, reverse run signal input terminal P087 Multi-function control signal SW1 input terminal P19, P20, P218 Multi-function control signal SW2 input terminalFrequency setting signal changeover input terminalP19 to P21P22 to P249 Multi-function control signal SW3 input terminalPWM signal input terminalP19 to P21P22 to P2410 Open collector output terminal (C: collector) P2511 Open collector output terminal (E: emitter) P25A Relay contact output terminal (NO: at factory setting) P26B Relay contact output terminal (NC: at factory setting) P26C Relay contact output terminal (COM) P26Control Circuit Wiring∗ Only basic insulation (Protection against Electric Shock Class I, Overvoltagecategory II, Pollution degree 2) is provided on the control circuit terminals.The supplementary insulation must be provided on the final product to complywith CE Marking requirements.