242. Forward/reverse run operation1) Forward run/reverse run method (Parameter P08 set to "1")Press the button (forward run) or button (reverse run) on the panelto select the rotation direction. Operation will start when the RUN buttonis pressed, and will stop when the STOP button is pressed.∗ The inverter will not start running just by pressing the RUN button.∗ The MOP function cannot be used if the frequency is set with thedigital method.2) Start/stop, rotation direction mode setting method (Parameter P08 set to"0")First, press the MODE button twice to enter the rotation direction settingmode. Press the SET button to display the rotation direction data,change the rotation direction with the (up) button and (down) button,and then press the SET button to enter the data. (Forward run is set asthe factory setting.)Operation will start when the RUN button is pressed, and will stop whenthe STOP button is pressed.3. Combination of "MOP function", "rotation direction setting mode",and forward/reverse run operationForward/reverse run operation MOP function Details of rotation directionsetting modeForward run/reverse run method × (Cannot be used) Only monitor functionStart/stop, rotation direction modesetting method { (Can be used) Monitor function and direction settingNote) When the forward/reverse run operation is set to "forward run/reverse run method", the MOP function cannot be used even if thefrequency is set with the digital method.