26Operating with the operation panel - 2· Forward/reverse run operation:Forward run/reverse run (Parameter P08=1)· Frequency setting: Potentiometer setting (Parameter P09=0)[Monitoring and setting the potentiometer frequency command beforeoperation]Power ONGradually turn the frequency setting dial clockwise.The motor will start rotating, and will reach 25Hz operationwhen 25.0 is displayed.Forwardrun settingPress the (up) button, and set the rotation direction toforward run. (Press the button to set reverse run.)· Current state (0: Stop, F: Forward run, r: Reverse run)· Set rotation direction (F: Forward run, r: Reverse run)RuncommandPress the RUN button.The run state will be entered, but as the frequency setting dialis set to Min., the 0V stop state will be entered.RUNThe main display lamp will turn[Example for rotating in forward direction at operating frequency 25Hz][Example to set operating frequency to 50Hz]ChangingthefrequencyTurn the frequency setting dial clockwise, and set to theMax. position. The motor speed will increase and reach50Hz in approx. 2.5 seconds.[Stopping operation]StopcommandPress the STOP button.The motor will start to decelerate and will stop in approx. 5seconds.STOPFrequencysettingMain display2 5. 0 F00. 00 005 0. 00 0 0Turn the frequency setting dial clockwise, and set thefrequency command to 25Hz.Checkingand settingtheoperat-ingfrequen-cyMODESETPress the MODE button.MODEPreparingfor operationPress the MODE button four times.(Fr ⇒ dr ⇒ P01 ⇒ 000)Press the SET button and check the frequency command.Power ON The main display lamp will turn ON.Carry out [Forward run setting] ⇒ [Run command] explained above.0 00F r0. 02 5. 00 000