2-83.3. Dip Switch Setting8 Peel the RS485 Setting Label which covers switch holeson top of the camera.8 Set the DIP switches (SW1, 2) on the Switch Board asshown in Fig. 3-3-1.8 Stick the labels as it was.3.4. Setting Up for Standard Picture8 The adjustment should be done after 30 minutes warm-up.8 Set the Logarithmic Gray Scale Chart.8 Incident light of 1 400 lx ± 50 lx on the Logarithmic GrayScale Chart.8 Aim the Camera at the Logarithmic Gray Scale Chart.8 Set the Camera by the Remote E.V.R. Adjustment Kit sothat the Logarithmic Gray Scale Chart becoms full pic-ture on the Underscanned Colour Video Monitor.8 Adjust the Lens Focus by the Remote E.V.R. AdjustmentKit to obtain correct focal point.8 The adjustments should be done with this StandardPicture, unless otherwise specified.(4) Installing E.V.R Adjustment Program8 Make a copy of following necessory files to your comput-er from original floppy disk.RADJ2.EXECW97C.SEQCW97AF1.SEQCW97TLT.SEQCW97PRE.SEQCW97C.EV28 The Example given here is for A 2 drive computer, yourprocedure might vary slightly depending on the driveconfiguration.8 Confirm that the contents of CONFIG.SYS file on yourcomputer is DEVICE=ANSI.SYS (Basic).8 Insert floppy disk containing the E.V.R. AdjustmentProgram into your floppy drive (for example,drive:A) andtype A:8 At the prompt, type CD IBMPC and press ENTER key.8 Type COPY RADJ2.EXE B: and press ENTER key.8 Type CD\ and press ENTER key.8 Type CD SEQ and press ENTER key.8 Type COPY CW97C.SEQ B: and press ENTER key.8 Type COPY CW97AF1.SEQ B: and press ENTER key.8 Type COPY CW97TLT.SEQ B: and press ENTER key.8 Type COPY CW97PRE.SEQ B: and press ENTER key.8 Type CD\ and press ENTER key.8 Type CD EVR and press ENTER key.8 Type COPY CW97C.EV2 B: and press ENTER key.8 After completing installation of program, you are ready touse the E.V.R. Adjustment Program.RS485SettingS TA R TON1 2 3 4 5 6 7 8ON1 2 3 4SW1SW2Camera top viewRS485 Setting LabelDIP SwitchesSW24-bit DIP SW#1 : ON, #2-#4 : OFFSW18-bit DIP SW#1-#8 : OFFFig. 3-3-1