• Alarm input(TRM2): Receives alarms. When “Alarm input” is selected, a pull-down menu for “Close” and“Open” is displayed.– Close: An alarm is detected when the terminal status is changed to “Close”.– Open: An alarm is detected when the terminal status is changed to “Open”.• Alarm output: Alarm output will be carried out according to the settings for “Output terminal”(®page 128).• Default: Off[Terminal 3]S11x2S11x1S15x1S25x1S22x1S21x1Determine how to use terminal 3.• Off: Not used.• Alarm input(TRM3): Receives alarms. When “Alarm input” is selected, a pull-down menu for “Close” and“Open” is displayed.– Close: An alarm is detected when the terminal status is changed to “Close”.– Open: An alarm is detected when the terminal status is changed to “Open”.• AUX output: AUX output will be supplied. The [AUX] buttons will be displayed on the “Live” page.• Default: OffIMPORTANT• In order for the EXT I/O terminals to detect alarm inputs when the terminal status is changed from Opento Close (On) or from Close to Open (Off), about 100 ms or more is needed. Because alarms cannotbe detected for about 5 seconds after a detection is made, alarm inputs received within about 5 secondsafter an alarm is detected are not detected.Note• AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the “Live” page.For example, an operator can remotely control lights in a place where the camera is installed byconnecting the terminal to the light controller.• Refer to the Important Information on the provided CD-ROM for further information about input/outputrating of each terminal.[VMD alarm]When clicking “VMD >>”, the [VMD area] tab of the “Alarm” page will be displayed. (®page 138)[Audio detection alarm]When “Audio detection>>” is clicked, the [Audio detection] tab will be displayed. (®page 140)[Command alarm]Select “On” or “Off” to determine whether or not to receive the command alarm.The command alarm is the function that provides notification of a Panasonic protocol alarm from the othercameras. When “On” is selected, alarm actions will be performed between multiple cameras.• Default: Off[Reception port]Select a port number to be used to receive the command alarm.• Available range: 1-65535• Default: 8181The following port numbers are unavailable since they are already in use.20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000Operating Instructions 1272 Settings