Note• The total service time of 6 years is the total power-on time from the SD card being inserted. 2000 cyclesare the upper limit overwrite counts of the industrial SD memory card (MLC type). These are typicalvalues and not a guarantee of the SD card lifetime.• The output terminal and the SD memory card errors use the same output terminal.• A signal is outputted to the output terminal when either an alarm or SD memory card error occurs.• When an SD memory card error is detected, the [Alarm occurrence indication] button on the “Live”page blinks. If you click on the [Alarm occurrence indication] button, the button will be hidden.• Output signals from the output terminal for [SD memory card error] differ depending on the settings of[Terminal state upon alarm detection].– When “Latch” is selected: Even after you click the [Alarm occurrence indication] button and itdisappears, output signals from the output terminal will continue as long as the cause of the [SDmemory card error] is not resolved.– When “Pulse” is selected: Even after you click the [Alarm occurrence indication] button and itdisappears, output signals from the output terminal will continue as long as the cause of the [SDmemory card error] is not resolved. However, if the time period specified for [Pulse output width]is exceeded, output signals from the output terminal will be stopped.[Terminal state upon alarm detection]Select “Latch” or “Pulse” for the output terminal at an alarm occurrence.• Latch: When an alarm is detected, the output terminal will be in the state selected for “Terminal actionupon alarm detection” until the alarm occurrence indication button is clicked.• Pulse: When an alarm is detected, the output terminal will be in the state to the “Terminal action uponalarm detection” setting for the period set for “Pulse output width”. When the alarm occurrence indicationbutton is clicked, the output terminal will return to the normal state.• Default: Latch[Terminal action upon alarm detection]Select “Open” or “Close” to determine whether to open or close the output terminal when outputting the alarmsignals.• Open: The output terminal will open when outputting the alarm signals. (Normally close)• Close: The output terminal will close when outputting the alarm signals. (Normally open)• Default: CloseNote• When “Open” is selected, the alarm signal will be output for about 20 seconds when the power of theunit is turned on.[Pulse output width]When “Pulse” is selected for “Terminal state upon alarm detection”, select an output terminal duration from thefollowing.• Available range: 1-120s• Default: 1s2.7.3 Change the AUX name [Alarm]S11x2S11x1S15x1S25x1S22x1S21x1Click the [Alarm] tab on the “Alarm” page. (®page 41, page 42)Operating Instructions 1292 Settings