Parker EME Communication192-120101 N11 C3I11T11 November 2007 2395.2.2. Configuration of local modem 1 Menu "Options: Communication settings RS232/RS485..." must be opened Select "Connection via Modem" Under "name" you can enter a name for the connection Enter the target telephone number.Note: If an ISDN telephone system is operated within a company network, anadditional "0" may be required in order to get out of the local system into thecomany network before reaching the outside line with an additional "0". The timeout periods are set to reasonable standard values according to ourexperience. Select the modem type: "Westermo TD-33" or "user-defined modem" For "Westermo TD-33", no further settings are required. For "user-defined modem", additional settings are only required, if the modemdoes not support standard AT commands.Then you can enter special AT commands. Note: When operating the local modem on a telephone system, it may benecessary to make a blind dialling. Here, the modem does not wait for thedialling tone. For the Westermo TD33, the additional command sequence isATX3. Select the COM interface where the modem is connected. Close the window and establish the connection with button (open/close COMport). The connection is interrupted when the COM port is closed. Select the modem type: "Westermo TD-33" or "user-defined modem" For "Westermo TD-33", no further settings are required. For "user-defined modem", additional settings are only required, if the modemdoes not support standard AT commands.Then you can enter special AT commands. Note: When operating the local modem on a telephone system, it may benecessary to make a blind dialling. Here, the modem does not wait for thedialling tone. For the Westermo TD33, the additional command sequence isATX3.