Technical data Positioning via digital I/Os296 192-120101 N11 C3I11T11 November 2007Control voltage 24VDC Compax3S and Compax3HController type Compax3Voltage range 21 - 27VDCMains module with switch-on current limitation, due tocapacitive loadFuse MTP miniature circuit breaker or "delayed actionfuse", due to capacitive loadCurrent drain of the device 0.8ATotal current drain 0.8 A + Total load of the digital outputs +current for the motor holding brakeRipple 0.5VppRequirement according to safe extralow voltage (SELV)yesShort-circuit proof conditional (internally protected with 3.15AT)Control voltage 24VDC Compax3MP / Compax3MDevice type Compax3MP / Compax3MVoltage range 21 - 27VDCMains module with switch-on current limitation, due tocapacitive loadFuse MTP miniature circuit breaker or "delayed actionfuse", due to capacitive loadCurrent drain of the device C3MP10D6: 0.2ATotal current drain C3M050D6: 0.85AC3M100D6: 0.85AC3M150D6: 0.85A+ Total load of the digital outputs + current forthe motor holding brakeRipple 0.5VppRequirement according to safe extralow voltage (SELV)yesShort-circuit proof conditional (internally protected with 3.15AT)Output data Compax3S0xx at 1*230VAC/240VACController type S025V2 S063V2Output voltage 3x 0-240V 3x 0-240VNominal output current 2.5Aeff 6.3AeffPulse current for 5s 5.5Aeff 12.6AeffPower 1kVA 2.5kVASwitching frequency 16kHz 16kHzPower loss for In 30W 60WOutput data Compax3S1xx at 3*230VAC/240VACController type S100V2 S150V2Output voltage 3x 0-240V 3x 0-240VNominal output current 10Aeff 15AeffPulse current for 5s 20Aeff 30AeffPower 4kVA 6kVASwitching frequency 16kHz 8kHzPower loss for In 80 W 130W