A – Command Line InterfaceSet Config Command59056-03 C A-65ATable A-20. Set Config Switch ParametersParameter DescriptionAdminState Switch administrative state: online, offline, ordiagnostics. The default is Online.BroadcastEnabled Broadcast. Enables (True) or disables (False)forwarding of broadcast frames. The default isTrue.InbandEnabled Inband management. Enables (True) or disables(False) the ability to manage the switch over anISL. The default is True.FDMIEnabled Fabric Device Monitoring Interface. Enables (True)or disables (False) the monitoring of target andinitiator device information. The default is True.FDMIEntries The number of device entries to maintain in theFDMI database. Enter a number from 0–1000. Thedefault is 1000.DefaultDomainID Default domain ID. The default is 1.DomainIDLock Prevents (True) or allows (False) dynamicreassignment of the domain ID. The default isFalse.SymbolicName Descriptive name for the switch. The name can beup to 32 characters excluding #, semicolon (;), andcomma (,). The default is SANbox.R_A_TOV Resource Allocation Timeout Value. The numberof milliseconds the switch waits to allow two portsto allocate enough resources to establish a link.The default is 10000.E_D_TOV Error Detect Timeout Value. The number ofmilliseconds a port is to wait for errors to clear. Thedefault is 2000.PrincipalPriority The priority used in the FC-SW-2 principal switchselection algorithm. 1 is high, 255 is low. Thedefault is 254.ConfigDescription Switch configuration description. The configurationdescription can be up to 32 characters excluding#, semicolon (;), and comma (,). The default isConfig Default.