64EnglishOTHERSA Model(s) : AE160MXTPEH/AE160MNYDEHB Air-to-water heat pump : yesC Water-to-water heat pump : noD Brine-to-water heat pump : noE Low-temperature heat pump : noF Equipped with a supplementary heater : noG Heat pump combination heater : noH Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps.For low-temperature heat pump, parameters shall be declared for low-temperature application.I Parameters shall be declared for average climate conditions.Item (J) Symbol (K) Value (L) Unit (M) Item (J) Symbol (K) Value (L) Unit (M)N Rated heat output(*) Prated (o) 9 kW P Seasonal space heating energy efficiency ηs 120 %Q Declared capacity for heating for part load at indoor temperature 20 °Cand outdoor temperature T j R Declared coefficient of performance or primary energy ratio for part load atindoor temperature 20 °C and outdoor temperature T j-Tj = -7 °C Pdh 7.8 kW-Tj = -7 °C COPd (S) 2.01 -Tj = +2 °C Pdh 4.7 kW Tj = +2 °C COPd (S) 2.97 -Tj = +7 °C Pdh 3.0 kW Tj = +7 °C COPd (S) 3.73 -Tj = +12 °C Pdh 1.4 kW Tj = +12 °C COPd (S) 5.52 -T Tj = bivalent temperature Pdh 8.8 kW T Tj = bivalent temperature COPd (S) 1.83 -U Tj = operation limit temperature Pdh 8.8 kW U Tj = operation limit temperature COPd (S) 1.83 -V For air-to-water heat pumpsTj = -15 °C (if TOL < -20 °C) Pdh - kW V For air-to-water heat pumpsTj = -15 °C (if TOL < -20 °C) COPd (S) - -W Bivalent temperature Tbiv -10 °C X For air-to-water heat pumps:Operation limit temperature TOL -10 °CY Cycling interval capacity for heating Pcych - kW Z Cycling interval efficiency COPcyc(AA) - -AB Degradation co-efficient(**) Cdh 0.9 - AC Heating water operating limittemperature WTOL - °CAD Power consumption in modes other than active mode AE Supplementary heaterAF Off mode POFF 0.080 kW N Rated heat output(*) Psup - kWAG Thermostat-off mode PTO 0.011 kWAJ Type of energy inputAH Standby mode PSB 0.011 kWAI Crankcase heater mode PCK 0.000 kWAK Other items AK Other itemsAL Capacity control variable (AM) AN For air-to-water heat pumps :Rated air flow rate, outdoors - 6180 m3/h (AO)AP Sound power level, indoors/outdoors LWA 53/73 dB ARFor water-/brine-to-water heat pumps:Rated brine or water flow rate, outdoorheat exchanger- - m3/h (AO)AQ Emissions of nitrogen oxides NOx - mg/kWhAS For heat pump combination heater AS For heat pump combination heaterAT Declared load profile - AU Water heating energy efficiency ηwh - %AV Daily electricity comsumption Qelec - kWh AW Daily fuel consumption Qfuel - kWhAX Contact details http://www.samsung.comAY(*) For heat pump space heaters and heat pump combination heaters, the rated that output Prated is equal tothe design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to thesupplementary capacity for heating sup(Tj).AZ (**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.BA 1) Precautions as described in the installation/user manual must be taken when assembling, installing and maintainingthis product.BB 2) If you are a professional looking for information on non-destructive disassembly and dismantling, please send anemail to: erims.sec@samsung.comCOMMISSION REGULATION (EU) No 813/2013 I)