PART 2. HARDWARE DESCRIPTIONS2.1 SYSTEM CABINETSThe cabinets that make up the OfficeServ 7200 system are of metal construction and may be utilized as either asan expansion cabinet or as a main cabinet / key service unit (KSU). The cabinets may be used individually or maybe stacked up to two (2) high to achieve maximum capacity. A single cabinet may be wall mounted for smallerapplications or alternatively the system may be mounted in a standard nineteen inch (19”) equipment rack. Eachcabinet is comprised of the following:• Five (5) interface card slots• One processor card slot• One power supply (installed in back panel of the cabinet)• AC power connector• DC power (Battery Backup) connector2.2 PROCESSOR CARDSThe OfficeServ 7200 requires a processor card or cards in order to operate. In a single cabinet OfficeServ 7200 sys-tem, only one processor card, the Main Control Processor (MCP), is required. Each expansion cabinet requires itsown Local Control Processor (LCP). These processor cards are described below.MAIN CONTROL PROCESSOR (MCP)The Main Control Processor (MCP) is installed in a dedicated processor slot, slot 0, of the first cabinet and has posi-tions for three daughter boards. The first daughter board position (labeled “MIS”) can support the MIS daughterboard ONLY. The second daughter board position is only for the RCM or RCM2 daughter boards. The third daugh-ter board position is dedicated only for the MFM daughter board.The MCP includes without additional daughter boards the following common system resources: 4 DTMFReceivers and 32 DTMF Senders.Note: The four types of daughter boards mentioned above can only reside on the MCP.LOCAL CONTROL PROCESSOR (LCP)The Local Control Processor (LCP) card is installed in a dedicated processor slot, slot 0, of the expansion cabinet.The LCP controls the interface boards in the expansion cabinet and communicates with the MCP. A three (3) wirelink cable connects the LCP to the MCP.2.1MAIN CONTROL PROCESSOR (MCP) DAUGHTER BOARD CAPABILITIESPosition Types of Daughter Boards allowed per positionMCP - D1 MISMCP - D2 RCM, RCM2MCP - D3 MFM