3-14Alignment and AdjustmentsSamsung Electronics3-3-5(d) Check After Adjustment1) Tracking CheckŒ Playback the alignment tape.´ Confirm that the minimum amplitude value(E min.)is 80% of the maximum value(E max.) or larger.(Fig. 3-19)ˇ Confirm that no large fluctuation occur on the waveform. (Fig. 3-20)2) CUE and REV CheckŒ Playback the alignment tape, and set to REV mode.Confirm that the waveform peaks have a uniform Pitch. (Fig. 3-21 A)If the track pitch is not uniform, do section 3-3-5(b) (Tracking adjustment).´ Set to CUE mode.Confirm that the waveform peaks still have a uniform pitch. (Fig. 3-21 B)If the track pitch is not uniform, do section 3-3-5(b) (Tracking Adjustment).Emin EmaxEmaxEmin 80(%)Fig. 3-19AACCC18Fig. 3-20a b c aa b cb cFig. 3-21