PLC-WL2500A / WL2501A/ WL2503A Expand Serial Command Functional Specifications69/729.12 Other Status Read Command9.12.1 CR_STATUS CommandCommand “CR_STATUS”(CR)DetailsGet status of Projector behavior.This command affects the same as ”CR0” of Basic Serial command, but this hasan error code.ResponseAcceptable “000_%1”[CR]%1“00”= Power ON“80”= Stand by“40”= Count down“20”= Cooling down“10”= Power failure“28”= Cooling down due to abnormal temperature“88”= Stand by after Cooling down“24”= Power saving cooling down“04”= Power saving“21”= Cooling down due to Lamp failure“81”= Stand by after Cooling down due to Lamp failureUnacceptable “Error Code”[CR]9.12.2 CR_SIGNAL CommandCommand “CR_SIGNAL”(CR)Details Get Signal status if there is signal or notResponseAcceptable “000_%a”[CR]%a “ON” ------------------------ Signal is found“OFF” ----------------------- There is no signalUnacceptable “Error code”[CR]9.12.3 CR_VMUTE CommandCommand “CR_VMUTE”[CR]Details Get setting status of No ShowResponseAcceptable “000_%a”[CR]%a “ON” -------- No Show is ON“OFF” ------- No Show is OFFUnacceptable “Error code”[CR]9.12.4 CR_FREEZE CommandCommand “CR_FREEZE”[CR]Details Get setting status of FreezeResponseAcceptable “000_%a”[CR]%a “ON” ---------------------- Freeze is ON“OFF” --------------------- Freeze is OFFUnacceptable “Error code”[CR]