PLC-WL2500A / WL2501A/ WL2503A Expand Serial Command Functional Specifications72/729.12.7 CR_TEMPFAIL CommandCommand "CR_TEMPFAIL”[CR]DetailsGet the temperature inside a projector when abnormal temperature occurs.If there are several sensors installed, it is possible to get information from all thesensors at once.ResponseAcceptable “000_%a_%b_%c”[CR]%a%b%c%a ------------------ Sensor 1 temp. (External temp.)%b ------------------ Sensor 2 temp. (Internal temp.1)%c ------------------ Sensor 3 temp. (Internal temp.2)[Example]“_31.5F”[CR]“_” indicates a space. When the temperature sinks to -, the firstcharacter is “-” like “-05.5F”[CR]The last character means the sensor’s status if it reachesabnormal temperatureExceeding critical temp. ------------------------------ “F”Temp. is safe -------------------------------------------- “S”Sensor detects no critical temp.--------------------- “N”The example shows that sensor 1 indicates 31.5 degrees and thetemperature is abnormal.When the temperature is safe, all data are represented as“□000S”.When the projector is reset, “□000S” is set, and every timeabnormal temperature occurs, it renews the data and returns it.In short, it only returns the renewed data of the latest abnormaltemperature and the previous data is deleted.Unacceptable “Error code”[CR]