Part No. 824982 Genie TZ-50 4 - 27January 2016 Section 4 • Repair Procedures5 Locate the outrigger level sensors locatedbelow the ground control panel. Refer to thefollowing illustrations.a tilt level sensorb outrigger level sensorc autolevel relay (early production)d "X" indicatore adjusting fastenerIf you are not installing a new level sensor,proceed to step 10.6 Tag and disconnect the wire harness from theoutrigger level sensor.7 Remove the three level sensor retainingfasteners. Remove the level sensor from themachine.8 Install the new level sensor onto the machinewith the "X" on the level sensor housing locatedas shown in the illustrations. Install and tightenthe level sensor retaining fasteners.9 Connect the wire harness to the level sensor.10 Tighten the level sensor adjusting fastenersuntil the bubble in the top of the level sensor iscentered in the circles.Note: Be sure there are threads showing throughthe top of the adjusting fasteners.11 Turn the key switch to ground control.12 Raise the outriggers until all of the outriggersare off the ground.13 Push and hold the yellow function enablebutton. Push and hold the auto level button.Result: The outriggers will lower and adjust tolevel the machine and raise the wheels off theground. Use the bubble level located below theground controls to confi rm that the machine islevel.CR66AUTOLEVELRELAYcYXYXYXa bddd ebdbYXYXad eGROUND CONTROLS