61OPERATING MANUALVERSION 05/2017 ORDER NUMBER DOC 2354920 SPRINT XE12.5.2 SWITCHING THE GUN TYPESNote:Clean the powder residues from all powder-conveying parts thoroughly, before changingto another gun type.P_01785EPG SPRINT X0 %1020304050Ø12101198m /h2.03.00.50.30.11.535.54.53.52.580100 %Tri90607012P_02719Procedure:(For example: switching from Corona to Tribo)1. Switch off control unit with switch 1 on the rear or with "Standby" button 15 on thefront.2. Change the coating powder from Corona to Tribo.3. Disconnect the hose (2) (transparent, atomizing air) from the Corona gun andconnect it to the Tribo gun (Tribo air).4. Disconnect the powder feed hose of the Corona spray gun from the powder injectorand connect the Tribo gun hose to the powder injector.5. Set the switch (C) on the switchbox to Tribo.6. Switch on control unit with switch 1 on the rear or with "Standby" button 15 on thefront.Note:Parameter C11, in the EPG-Sprint XE control unit device configuration, must be set to"aut". No gun is selected at first after the control unit is switched on. This will however beautomatically selected and displayed after 1 second.