122 Appendix WAGO-I/O-SYSTEM 750750-657 IO-Link MasterManualVersion 1.0.2, valid from FW/HW-Version 02/0111.3.5 IOL-M Directory RecordDo not confuse the "IOL-M Directory" record with "IOL-M Basic/PortConfiguration"!Do not confuse the "IOL-M directory" record with the data of the "OL-M Basicconfiguration" and "IOL-M Port configuration" records.The "IOL-M directory" only contains information about the IO-Link master itselfand is read only.Table 117: IOL-M Directory RecordParameter Data type Access DescriptionIO-Link Version UNSIGNED8 ro Supported IO-Link revision of the masterIO-Link Profile Version UNSIGNED8 ro IO-Link profileIO-Link Feature Support UNSIGNED32 ro Bit fields that display featuresNumber of Ports UNSIGNED8 ro Number of IO-Link ports availableREF Port Config UNSIGNED8 ro Index to port configurationREF IO Mapping UNSIGNED8 ro Index to I/O mappingREF iPar Directory UNSIGNED8 ro Index to iPar directorREF IOL M UNSIGNED8 ro Index to IOL-M parametersNumber of CAP UNSIGNED8 ro Number of client access points11.3.5.1 IO-Link VersionTable 118: Master configuration, “IO-Link Version“Name Access Value DescriptionIO-Link-Version ro 0x10: IO-Link 1.00x11: IO-Link 1.1Supported IO-Link revision of master11.3.5.2 IO-Link Profile VersionTable 119: Master configuration, “IO-Link Profile Version“Name Access Value DescriptionIO-Link Profile Version ro 0x00 IO-Link profile11.3.5.3 IO-Link Feature SupportTable 120: Master configuration, “IO-Link Feature Support”Name Access Value DescriptionIO-Link Feature Support ro 0x00000000 IO-Link feature support