8 Output Assemblies (Drive Consumes)YASKAWA ELECTRIC SIEP C730600 58A 1000-Series Option SI-EN3 Technical Manual EN 25OutputInstance Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 01160Multi-FunctionInput 8Multi-FunctionInput 7Multi-FunctionInput 6Multi-FunctionInput 5Multi-FunctionInput 4Multi-FunctionInput 3RunRevRunFwd1Multi-FunctionPhotoCoupler 2Multi-FunctionPhotoCoupler 1Multi-FunctionDigitalOutput– – – FaultResetExternalFault2 Speed Reference (Low Byte)3 Speed Reference (High Byte)4 Torque Reference/Torque Limit (Low Byte)5 Torque Reference/Torque Limit (High Byte)6 Torque Compensation (Low Byte)7 Torque Compensation (High Byte)8 (Reserved)9 – – – –Multi-FunctionInput 12Multi-FunctionInput 11Multi-FunctionInput 10Multi-FunctionInput 910 – – – – – – NetCtrl NetRef11 – – – – – – – –12 Analog Output 1 (Low Byte)13 Analog Output 1 (High Byte)14 Analog Output 2 (Low Byte)15 Analog Output 2 (High Byte)16 Digital Outputs (Low Byte)17 Digital Outputs (High Byte)18 Reserved19 Reserved20 - 21Programmable BytesDefined by F7-23Default: Not Used22 -23Programmable BytesDefined by F7-24Default: Not Used24 - 25Programmable BytesDefined by F7-25Default: Not Used26 - 27Programmable BytesDefined by F7-26Default: Not Used28 - 29Programmable BytesDefined by F7-27Default: Not Used30 - 31Programmable BytesDefined by F7-28Default: Not Used32 - 33Programmable BytesDefined by F7-29Default: Not Used11634 - 35Programmable BytesDefined by F7-30Default: Not Used36 - 37Programmable BytesDefined by F7-31Default: Not Used38 - 39Programmable BytesDefined by F7-32Default: Not Used40 - 43 Not Used