www.dadehpardazan.ir 88594014-152 Panel Operator2-42.2 Utility Functions (Fn)The utility functions are related to the setup and adjustment of the SERVOPACK.In this case, the panel operator displays numbers beginning with Fn.Display Example for Origin SearchThe following table outlines the procedures necessary for an origin search (Fn003).Step Display afterOperation Keys Operation1 Press the MODE/SET Key to select the utility function.2 Press the UP or DOWN Key to select Fn003.3 Press the DATA/SHIFT Key for approximately one sec-ond, and the display shown on the left appears.4 Press the MODE/SET Key to turn the servomotor powerON. The display shown on the left appears.5Pressing the UP Key will run the servomotor in the for-ward direction. Pressing the DOWN Key will run the ser-vomotor in the reverse direction. The movement directionof the servomotor changes according to the setting ofPn000.0 as shown in the following table.Note: Forward movement is the linear scale counting updirection. Refer to 5.2.3 Servomotor MovementDirection.6Display flashes.When the servomotor origin search is completed, the dis-play flashes.At this moment, the servomotor is servo-locked at the ori-gin pulse position.7 Press the DATA/SHIFT Key for approximately one sec-ond. "Fn003" is displayed again.8 To enable the change in the setting, turn the power OFF and ON again.AnalogMODE/SET DATA /MODE/SET DATA /MODE /SET DATA/MODE/SET DATA/MODE /SET DATA/Parameter UP Key DOWN KeyPn000n.0 Linear scalecounting upLinear scalecounting downn.1 Linear scalecounting downLinear scalecounting upMODE/SET DATA /