6.7 Clearing Alarm History (Fn006)6-136 Utility Functions (Fn)6.7 Clearing Alarm History (Fn006)The clear alarm history function deletes all of the alarm history recorded in the SERVOPACK.Note: The alarm history is not deleted when the alarm reset is executed or the main circuit power supply of the SERVO-PACK is turned OFF.(1) PreparationThe follow conditions must be met to clear the alarm history.• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).(2) Operating ProcedureUse the following procedure.Step Display after Operation Keys Operation1Press the Key to view the main menu for theutility function.Use the or Key to move through the list andselect Fn006.2 Press the Key. The display changes to the Fn006execution display.3Press the Key to clear the alarm history.While clearing the data, "DONE" is displayed in thestatus display. After the data has been successfullycleared, "BB" is displayed.Note: Press the Key not to clear the alarm his-tory. The display returns to the main menu ofthe utility function.B B − F U N C T I O N −F n 0 0 5 : P r m I n i tF n 0 0 6 : A l m H i s t C l rF n 0 0 8 : M t u r n C l rF n 0 0 9 : R e f A d jB BA l a r m H i s t o r yD a t a C l e a rS t a r t : [ D A T A ]R e t u r n : [ S E T ]B BA l a r m H i s t o r yD a t a C l e a rS t a r t : [ D A T A ]R e t u r n : [ S E T ]