B.5 E: Motor Parametersu E1: V/f Pattern for Motor 1No.(Addr.Hex) Name LCD Display Description Values PageE1-01(300) Input Voltage Setting Input VoltageThis parameter must be set to the power supply voltage.WARNING! Electrical Shock Hazard. Drive input voltage(not motor voltage) must be set in E1-01 for the protectivefeatures of the drive to function properly. Failure to do somay result in equipment damage and/or death or personalinjury.Default: 661.3 VMin.: 445.6Max.: 733.1 128E1-03(302) V/f Pattern SelectionV/F Selection0: 50 Hz1: 60 Hz Saturation2: 60 Hz Saturation3: 72 Hz4: 50 Hz VT15: 50 Hz VT26: 60 Hz VT17: 60 Hz VT28: 50 Hz HST19: 50 Hz HST2A: 60 Hz HST1B: 60 Hz HST2C: 90 HzD: 120 HzE: 180 HzF: Custom V/F0: 50 Hz, Constant torque 11: 60 Hz, Constant torque 22: 60 Hz, Constant torque 3 (50 Hz base)3: 72 Hz, Constant torque 4 (60 Hz base)4: 50 Hz, Variable torque 15: 50 Hz, Variable torque 26: 60 Hz, Variable torque 37: 60 Hz, Variable torque 48: 50 Hz, High starting torque 19: 50 Hz, High starting torque 2A: 60 Hz, High starting torque 3B: 60 Hz, High starting torque 4C: 90 Hz (60 Hz base)D: 120 Hz (60 Hz base)E: 180 Hz (60 Hz base)F: Custom V/f E1-04 through E1-13 settings define the V/fpatternDefault: F <1>Range: 0 to 9;A to F167B.5 E: Motor ParametersYASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual 283B Parameter List