B.12 T: Motor TuningEnter data into the following parameters to tune the motor and drive for optimal performance.u T1: Induction Motor Auto-TuningNo.(Addr.Hex) Name LCD Display Description Values PageT1-01(701)<1>Auto-Tuning ModeSelectionTuning Mode Sel2: Term Resistance3: On-DelayCompTune2: Stationary Auto-Tuning for Line-to-Line Resistance3: Rotational Auto-Tuning for V/f Control Energy Saving Default: 2Range: 2, 3 140T1-02(702) Motor Rated Power Mtr Rated PowerSets the motor rated power as specified on the motor nameplate.Note: Use the following formula to convert horsepowerinto kilowatts: 1HP = 0.746 kW.Default: <2>Min.: 0.00 kWMax.: 650.00kW140T1-03(703) Motor Rated Voltage Rated VoltageSets the motor rated voltage as specified on the motor nameplate. Default: 575.0VMin: 0.0Max: 733.1140T1-04(704) Motor Rated Current Rated CurrentSets the motor rated current as specified on the motor nameplate. Default: <2>Min.: 10% ofdrive ratedcurrentMax.: 200% ofdrive ratedcurrent141T1-05(705) Motor Base Frequency Rated FrequencySets the rated frequency of the motor as specified on the motornameplate. Default: 60.0HzMin.: 0.0Max.: 240.0141T1-06(706) Number of Motor Poles Number of Poles Sets the number of motor poles as specified on the motornameplate. Default: 4Min.: 2Max.: 48 141T1-07(707) Motor Base Speed Rated SpeedSets the rated speed of the motor as specified on the motornameplate. Default: 1750 r/minMin.: 0Max.: 14400141T1-11(70B) Motor Iron Loss Mtr Iron Loss(W)Sets the iron loss for determining the Energy Saving coefficient.The value is set to E2-10 (motor iron loss) set when the power iscycled. If T1-02 is changed, a default value appropriate for themotor capacity that was entered will appear.Default: 14 W<3>Min.: 0Max.: 65535141T1-12(FFF0) T1 Tuning Start Tuning Ready The drive starts tuning. No settingavailable 141<1> The availability of certain Auto-Tuning methods depends on the control mode selected for the drive.<2> Default setting is dependent on parameter o2-04, Drive Model Selection.<3> Default setting value differs depending on the motor code value and motor parameter settings.u T2: PM Motor Auto-TuningNo.(Addr.Hex) Name LCD Display Description Values PageT2-01(750) PM Motor Auto-TuningMode Selection PM Tuning Mode0: Standard TuningOLV/PMOLV/PM0: PM Motor Parameter SettingsDefault: 0Range: 0 –T2-03(752) PM Motor Type PM Motor Type0: IPM motor1: SPM motorOLV/PMOLV/PM0: IPM motor1: SPM motorDefault: 1Range: 0, 1 –T2-04(730) PM Motor Rated Power Mtr Rated PowerOLV/PMOLV/PMSets the motor rated power.Note: Use the following formula to convert horsepowerinto kilowatts: 1 HP = 0.746 kW.Default: <1>Min.: 0.00 kWMax.: 650.00kW–B.12 T: Motor TuningYASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual 315B Parameter List