PERIODIC MAINTENANCE AND ADJUSTMENT7-161234567891011126. Remove the coolant reservoir cap.7. Remove the coolant reservoir byremoving the bolts, and then turnthe reservoir upside down to emp-ty it.8. After the coolant is completelydrained, thoroughly flush the cool-ing system with clean tap water.9. Install the coolant reservoir by in-stalling the bolts.10. Install the coolant drain bolt and itsnew gasket, and then tighten thebolt to the specified torque.11. Pour the specified amount of therecommended coolant into the ra-diator and reservoir.12. Install the coolant reservoir cap.13. Loosen the air bleed bolt to allowany trapped air to escape from thewater pump.14. When coolant begins to flow out,tighten the air bleed bolt to the1. Coolant drain bolt2. Gasket1. Coolant reservoir cap1211. Coolant reservoir2. BoltTightening torque:Coolant drain bolt:10 Nm (1.0 m·kgf, 7.2 ft·lbf)12Antifreeze/water mixture ratio:1:1Recommended antifreeze:High-quality ethylene glycol anti-freeze containing corrosion inhibitorsfor aluminum enginesCoolant quantity:Radiator (including all routes):2.25 L (2.38 US qt, 1.98 Imp.qt)Coolant reservoir (up to the maxi-mum level mark):0.25 L (0.26 US qt, 0.22 Imp.qt)1. Air bleed bolt12CR-9-E0_1.book 16 ページ 2015年1月5日 月曜日 午前11時54分