Nortel BCM1000 manuals
BCM1000
Table of contents
- North American Regulatory Information
- Enhanced 911 Configuration
- Telecommunication registration
- Electromagnetic Compatibility
- Canadian Regulations - please read carefully
- US Regulations - please read carefully
- EMI/EMC (FCC Part 15)
- Important Safety Instructions
- International Regulatory Information
- Additional Safety Information
- Limited Warranty
- Warranty Repair Services
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Preface
- Symbols used in this guide
- Text conventions
- Related publications
- System documentation map
- Installation documentation
- Operations documentation
- Call Management documentation
- Unified Manager and hardware maintenance documentation
- how to get help
- Introducing the Business Communications Manager
- Computer components
- Figure 3 BCM1000 interior components for standard system (pre-2.5)
- Figure 4 BCM1000 interior components with a standard power supply system (2.5)
- Telephony components
- Data networking components
- MSC IP call processing hardware
- Connection ports
- BCM1000 LEDs
- System options
- Data features
- Business Communications Manager expansion unit
- Installation process overview
- Telephony hardware
- Media bay module common features
- Power connections
- DIP switches
- Trunk media bay modules
- Digital Trunk media bay module
- Global Analog Trunk Module (GATM)
- Caller ID Trunk media bay module
- Basic Rate Interface media bay module
- Station media bay modules
- Digital Station media bay module
- X16 media bay module
- Analog Station media bay module
- Global Analog Station media bay module (GASM8)
- Fiber Expansion media bay module
- Digital drop and insert MUX (DDIM)
- Telephones and adapters
- Cordless and wireless systems
- Digital 7406 system components
- Auxiliary requirements
- Browser requirements
- Preloading Java class files on your workstation
- Selecting the media bay modules for your system
- Selecting the trunk media bay modules
- Selecting the station media bay modules
- Upgrading from an existing Norstar system
- Changing the DS30 split
- Setting Offsets
- Figure 26 Offsets are part of DS30 line/DN groups
- Determining module DS30 bus requirements
- Table 10 Matching modules to DS30 bus capacity
- Installing the BCM1000
- Electrical requirements
- Analog loop
- Equipment for Installing the BCM1000
- Installing the BCM1000 into the rack
- Installing the BCM1000 on the wall
- Figure 30 Attaching the mounting brackets to the BCM1000
- Figure 31 Mount the BCM1000 on the wall
- Installing the BCM1000 on a flat surface
- Installing the BCM1000e (expansion unit)
- Attaching the BCM1000e to the rack
- Installing the BCM1000e on the wall
- Installing the BCM1000e on a flat surface
- Figure 36 BCM1000 DS258 connector
- Setting media bay module DIP switches
- Choosing the assigned order for modules
- Figure 37 Assigning the modules to the DS30 bus hierarchy
- Figure 38 Assigning double density modules to the DS30 bus hierarchy
- Determining module DIP switch settings
- Table 11 Possible media bay module DIP switch settings, single density
- Table 12 Possible media bay module DIP switch settings for double density
- Setting the DIP switches on the modules
- Line and extension numbers for specific modules
- BRI switch settings
- CTM/GATM switch settings
- GATM switch settings
- CTM/GATM DIP switch settings
- Table 18 Global Analog Trunk Module DIP switch settings
- X16 switch settings
- ASM 8/GASM8 switch settings
- GASM8 country switch settings
- DSM switch settings
- Table 23 DSM single density settings for BCM 2.5 systems upgraded to BCM 3.0 or newer software
- Table 25 DSM 16+ and DSM32+ double density switch settings for 2.5 systems upgraded to BCM 3.0 or newer software
- Table 26 DSM 16+ and DSM32+ double density switch settings for new systems with BCM 3.0 or newer software
- FEM switch settings
- Installing media bay modules
- Shutting down the system
- Installing a media bay module
- Figure 45 Warning of possible shorting issue on media bay modules
- Reconnecting the equipment
- Replacing media bay modules
- Installation/replacement troubleshooting
- Starting the system
- Checking power and wiring
- Checking system power and status
- Connecting the data networking hardware
- Connecting wiring to the LAN card
- Connect wiring to the modem card
- Table 30 RS-422/EIA 530 adapter cable
- Replacing the cards
- Setting initial system configurations
- Connecting when there is an IP address conflict
- Figure 50 Main Menu
- Using an Ethernet crossover cable
- Entering the software keycodes
- Wiring the modules
- Module wiring warnings
- Connecting media bay modules to Service Providers
- Figure 55 GATM cable wiring diagram
- Figure 56 BRI RJ45 wiring array
- Wiring media bay modules to internal connections
- Figure 57 Wiring for DSM 16, 4X16, and DSM 32
- Figure 58 Wiring for an ASM 8 or GASM8
- FEM wiring
- Table 36 Extension comparison chart
- Installing telephones and peripherals
- Central Answering Position (CAP/eCAP)
- Table 38 Cross referencing ports and DNs on a new version 3.0 or newer system
- Installing an emergency telephone
- Installing the 7406 cordless systems
- Installing Analog Terminal Adapters
- Connecting an analog telephone
- Connecting a data device
- Connecting the ATA 2
- Mounting the ATA 2
- Testing insertion loss measurement
- Configuring the ATA 2
- Installing optional telephony equipment
- External paging system
- Contents
- Connecting the external music source
- Troubleshooting
- Using the System Status Monitor to monitor LEDs
- Figure 70 LED locations on the face of the BCM1000
- Emergency telephone does not function
- ATA 2 does not function
- Checking for dial tone at the ATA 2
- Preparing hardware for maintenance or upgrades
- Shutting down the system software
- Shutting down the system hardware
- Removing the front bezel
- Software restart
- Replacing the hard disk
- Removing the hard disk
- Figure 77 Hard disk wiring (single disk) and screw locations (2.0 hardware)
- Figure 79 Remove the brackets from the hard disk
- Installing a new hard disk
- Figure 82 Cabling the RAID board to the hard disks
- Initializing the hard disk (single-disk system, BCM 2.5/2.5.1)
- Figure 84 Platform Initialization Menu screen (BCM 2.5/2.5.1 systems)
- Figure 85 Profile screen
- Initializing the hard disk (single-disk system, BCM 3.0)
- Figure 87 Platform Initialization Menu screen
- Initializing the hard disk (single-disk system BCM 3.0.1 and newer systems)
- Figure 89 Main Menu screen
- Figure 91 Initialization Menu screen
- Figure 93 System configuration start
- Figure 94 Quick start
- Installing the mirrored disk controller
- Installing the RAID board
- Connecting the RAID board
- Connecting RAID board ribbon cables
- Routing power for mirrored systems
- Power routing for 2.0 hardware
- RAID board LEDs
- Controlling and monitoring mirroring operations
- Adding or replacing a cooling fan
- Troubleshooting fan operation
- Figure 104 Remove the fan cable from motherboard (pre-2.5 chassis)
- Figure 106 Removing the fan (BCM1000 version 2.5 single-fan model)
- Replacing the cooling fan
- Removing a fan from the BCM1000e
- Figure 110 Fan screws location in BCM1000e, 2.0 models
- Replacing a fan into the BCM1000e
- Replacing a power supply
- Removing the standard power supply
- Installing a standard power supply
- Upgrading to a redundant power supply
- Setting up the base unit
- Installing the redundant power supply
- Figure 118 Attach the redundant power supply housing
- Figure 120 Insert and attach the modules
- Replacing a redundant power supply module
- Replacing a power supply in an BCM1000e
- Figure 123 BCM1000e, redundant power supply interior connections
- Replacing data cards and processing hardware
- Removing a data card
- Installing the card
- Replacing PECs
- Removing PECs
- Installing a PEC
- Replacing memory
- Replacing memory DIMM chips
- Replacing the clock/calendar battery
- Removing the clock/calendar battery
- Installing the new battery
- Moving and replacing telephones
- Moving telephones
- Replacing telephones with different models
- Defining region-based defaults
- Core software and regions
- Caller ID displays
- Companding Law by region
- Media bay module availability by region
- FEM-trunk module combinations by region
- PRI line protocol support, by region
- Supported ISDN line services
- Defining time zones by country and language
- Dialing plan defaults
- BRI and PRI line types
- CallPilot regions
- Table 60 CallPilot feature default anomalies
- Media bay module combinations
- Fully-loaded setup
- Table 63 Fully loaded system using modules set to double density
- Changing configurations
- Set DNs and port numbers
- Glossary
- Index
manualsdatabase
Your AI-powered manual search engine