ABB RED670 Relion 670 series manuals
RED670 Relion 670 series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1 Introduction
- Product documentation
- Document revision history
- Related documents
- Document symbols and conventions
- Section 2 Safety information
- Caution signs
- Note signs
- Section 3 Environmental aspects
- Section 4 Unpacking, inspecting and storing
- Returning an IED damaged in transit
- Section 5 Mounting
- Flush mounting
- Mounting procedure for flush mounting
- panel rack mounting
- Mounting procedure for 19" panel rack mounting
- Wall mounting
- Mounting procedure for wall mounting
- Side-by-side 19" rack mounting
- Mounting procedure for side-by-side rack mounting
- Side-by-side flush mounting
- Mounting procedure for side-by-side flush mounting
- Mounting the coupling capacitor unit REX061 and shunt resistor unit REX062 (REG670 only)
- Shunt resistor unit REX062
- Making the electrical connection
- Front side connectors
- Rear side connectors
- Connection examples for high impedance differential protection
- Connecting to protective earth
- Connecting the power supply module
- Connecting the binary input and output signals
- Making the shield connection
- Making the electrical connection to the rotor and stator injection equipment (REG670 only)
- Coupling capacitor unit REX061
- Connecting injection unit REX060, coupling capacitor unit REX061 and shunt resistor unit REX062
- Connecting and setting voltage inputs
- Making of Ethernet connections
- Connecting remote communication interfaces LDCM
- Installing the serial communication cable for RS485
- Installing the serial communication cable for RS485 SPA/IEC
- Data on RS485 serial communication module cable
- Electrical installation
- Section 7 Checking installation
- Section 8 Removing, repairing and exchanging
- Sending the IED for repair
- Section 9 Technical data
- Case with rear cover
- Flush mounting dimensions
- Side-by-side flush mounting dimensions
- Wall mounting dimensions
- Section 10 Glossary
RED670 Relion 670 series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1 Introduction
- Product documentation
- Document revision history
- Document symbols and conventions
- Document conventions
- Section 2 Safety information
- Caution signs
- Note signs
- Section 3 Environmental aspects
- Section 4 Unpacking, inspecting and storing
- Storing
- Section 5 Mounting
- Flush mounting
- Mounting procedure for flush mounting
- Mounting procedure for 19" panel rack mounting
- Wall mounting
- Side-by-side 19" rack mounting
- Mounting procedure for side-by-side rack mounting
- Side-by-side flush mounting
- Mounting procedure for side-by-side flush mounting
- Coupling capacitor unit REX061
- Shunt resistor unit REX062
- Section 6 Connecting
- Front side connectors
- Rear side connectors
- Connection examples for high impedance differential protection
- Connecting to protective ground
- Connecting to CT and VT circuits
- Connecting the binary input and output signals
- Making the shield connection
- Making the electrical connection to the rotor and stator injection equipment (REG670 only)
- Connecting injection unit REX060, coupling capacitor unit REX061 and shunt resistor unit REX062
- Connecting and setting voltage inputs
- Making of Ethernet connections
- Connecting remote communication interfaces LDCM
- Installing the serial communication cable for RS485
- Installing the serial communication cable for RS485 SPA/IEC
- Data on RS485 serial communication module cable
- Installing the GPS antenna
- Electrical installation
- Section 7 Checking installation
- Section 8 Removing, repairing and exchanging
- Exchanging the IED
- Section 9 Technical data
- Case with protective cover
- Flush mounting dimensions
- Side-by-side flush mounting dimensions
- Wall mounting dimensions
- Section 10 Glossary
RED670 Relion 670 series
Table of contents
RED670 Relion 670 series
Table of contents
- Table Of Contents
- Application
- Available functions
- Differential protection
- Impedance protection
- Current protection
- Voltage protection
- Frequency protection
- Secondary system supervision
- Scheme communication
- Logic
- Monitoring
- Metering
- Human machine interface
- Remote communication
- Connection diagrams
- Technical data
- Ordering for customized IED
- Ordering for pre-configured IED
- Ordering for Accessories
RED670 Relion 670 series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1 Introduction
- Product documentation
- Document revision history
- Related documents
- Document conventions
- IEC 61850 edition 1 / edition 2 mapping
- Section 2 Safety information
- Caution signs
- Section 3 Available functions
- Back-up protection functions
- Control and monitoring functions
- Communication
- Basic IED functions
- Section 4 Starting up
- Checking the power supply
- IED start-up sequence
- Writing an application configuration to the IED
- Checking CT circuits
- Checking VT circuits
- Checking the binary input/output circuits
- Checking optical connections
- Section 5 Configuring the IED and changing settings
- Configuring analog CT inputs
- Section 6 Establishing connection and verifying the SPA/IEC communication
- Verifying the communication
- Fibre optic loop
- Section 7 Establishing connection and verifying the LON communication
- The LON Protocol
- Optical budget calculation for serial communication with LON
- Section 8 Establishing connection and verifying the IEC
- Section 9 Establishing connection and verifying the IEEE C37.118/1344 communication
- Setting the PMU station communication (PMU configuration)
- Setting the TCP/UDP client communication
- Verifying the IEEE C37.118/1344 TCP communication
- Verifying the IEEE C37.118/1344 UDP communication
- Optical budget calculation for PMU - PDC communication
- Section 10 Testing IED operation
- Preparing the IED to verify settings
- Activating the test mode
- Connecting the test equipment to the IED
- Releasing the function to be tested
- Verifying analog primary and secondary measurement
- Testing the protection functionality
- Forcing of binary input/output signals for testing
- Enable forcing using TESTMODE function block
- Forcing by using PCM600
- operation
- Undo forcing by using TESTMODE component
- Testing disturbance report
- Event recorder (ER) and Event list (EL)
- Identifying the function to test in the technical reference manual
- Completing the test
- Verifying the settings
- Measuring the operating limit of set values
- Phase-to-earth faults
- Faulty phase identification with load encroachment FMPSPDIS
- Measuring the operating time of distance protection zones
- Testing the power swing detection function ZMRPSB
- Testing the block input, interaction between FDPSPDIS or FRPSPDIS and ZMRPSB
- Testing the carrier send and trip signals
- Checking the underreaching zone
- Pole slip protection PSPPPAM
- Automatic switch onto fault logic ZCVPSOF
- Activating ZCVPSOF externally
- Phase preference logic PPLPHIZ
- Four step residual overcurrent protection, (Zero sequence or negative sequence directionality) EF4PTOC
- Four step non-directional earth fault protection
- Measuring the operate and time limit for set values
- Checking the re-trip and back-up times
- Verifying the back-up trip mode
- Verifying instantaneous back-up trip at CB faulty condition
- Extended testing
- Check of voltage differential trip and alarm levels
- Check of trip and trip reset timers
- Final adjustment of compensation for VT ratio differences
- Built-in overcurrent feature (non-directional)
- Overcurrent feature with voltage restraint
- Over/Undervoltage feature
- Measuring the operate value for the negative sequence function
- Measuring the operate value for the zero-sequence function
- function
- Testing the synchronizing function
- Testing the energizing check
- Testing the voltage selection
- Autorecloser for 1/2/3-phase operation SMBRREC
- Preparation of the verification
- Checking the auto reclosing conditions
- Single command, 16 signals SINGLECMD
- Testing permissive underreaching
- Testing delta blocking scheme
- Testing permissive overreaching
- Current reversal and Weak-end infeed logic for distance protection 3-phase ZCRWPSCH
- Weak end infeed logic
- Local acceleration logic ZCLCPSCH
- Testing the weak-end infeed logic
- Direct transfer trip logic
- Sudden change in current variation SCCVPTOC
- Negative sequence overvoltage protection LCNSPTOV
- Zero sequence overvoltage protection LCZSPTOV
- Zero sequence overcurrent protection LCZSPTOC
- Three phase overcurrent LCP3PTOC
- Logic
- ph/3ph operating mode
- ph/2ph/3ph operating mode
- Circuit breaker lockout
- Testing the gas medium supervision for pressure alarm and pressure lockout conditions
- Testing the liquid medium supervision for temperature alarm and temperature lock out conditions
- Fault locator LMBRFLO
- Metering
- Station communication
- Overview
- clearing system
- Visual inspection
- Recording
- Measurement of service currents
- Restoring
- Section 14 Troubleshooting
- Fault tracing
- Using front-connected PC
- Diagnosing the IED status via the LHMI hint menu
- Repair instruction
- Repair support
- Section 15 Glossary
RED670 Relion 670 series
Table of contents
Related products
Relion 670 seriesRELION SeriesRelion 620 SeriesRELION 650 SERIESRelion 611 SeriesRelion 615 seriesRelion 630 SeriesRelion RES670Relion REC670RelionABB categories
Industrial Equipment
DC Drives
Controller
Relays
Measuring Instruments
Circuit breakers
Battery Charger
Industrial Electrical
Transformer
Switch
manualsdatabase
Your AI-powered manual search engine