Contents - List of related manuals
- 1. Safety instructions
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Contents of this chapter
- General safety in installation, start-up and maintenance
- Electrical safety in installation, start-up and maintenance
- Additional instructions and notes
- Grounding
- General safety in operation
- Contents of this manual
- Categorization by frame (size)
- Quick installation and commissioning flowchart
- Operation principle
- Layout
- Overview of power and control connections
- External control connection terminals, frames R0...R4
- External control connection terminals, frame R5...R9
- Control panel
- Type designation label
- Locations of the labels on the drive
- Type designation key
- Checking the installation site
- Required tools
- Moving the drive
- Unpacking and examining delivery, frame R5
- Frame R5 cable box (IP21, UL Type 1)
- Unpacking and examining delivery, frames R6...R9
- Frame R6 cable box (IP21, UL Type 1)
- Frame R7 cable box (IP21, UL Type 1)
- Frame R8 cable box (IP21, UL Type 1)
- Frame R9 cable box (IP21, UL Type 1)
- Installing the drive
- Installing the drive vertically side by side
- Other regions
- Typical power cable sizes
- Alternative power cable types
- Motor cable shield
- Selecting the control cables
- Relay cable
- Routing the cables
- Separate control cable ducts
- Implementing thermal overload and short-circuit protection
- Protecting the drive against ground faults
- Using a contactor between the drive and the motor
- Example bypass connection
- Protecting the contacts of relay outputs
- Limiting relay output maximum voltages at high installation altitudes
- Checking the insulation of the assembly
- Brake resistor assembly for R0...R3
- Ground-to-phase varistor
- Frames R0...R3
- Frames R4...R9
- Connecting the power cables
- Connection procedure, frames R0...R4
- Connection procedure, frame R5
- Connection procedure, frames R6...R9
- Motor cable
- DC connection
- Connecting the control cables
- Default I/O connection diagram (ABB standard macro)
- Control cable connection procedure R0...R9
- Installing option modules
- Wiring the modules
- Reinstalling covers
- Reinstalling covers, frame R5
- Reinstalling side plates and covers, frames R6...R9
- Connecting a PC
- Preventive maintenance intervals
- Heatsink
- Fans
- Replacing the cooling fan, frame R5
- Replacing the main cooling fans, frame R9
- Replacing the auxiliary cooling fan, frames R4...R9
- Capacitors
- LEDs
- Control panel LEDs
- Ratings
- NEMA ratings
- Sizing
- Ambient temperature derating, IP21
- Ambient temperature derating, IP55
- IP55 (UL Type 12) drive type -363A-4
- Switching frequency derating
- Fuses (IEC)
- gG fuses
- Dimensions, weights and free space requirements
- Cooling data and noise
- Terminal and lead-through data for the power cables
- Terminal and lead-through data for the control cables
- Electrical power network specification
- Brake resistor connection data for frames R0...R3
- Efficiency
- Materials
- CE marking
- Compliance with the EN 61800-3:2004 + A1:2012
- Category C2
- Category C4
- UL checklist
- Frame R0, IP21
- Frame R0, IP55
- Frame R1, IP21
- Frame R1, IP55
- Frame R2, IP21
- Frame R2, IP55
- Frame R3, IP21
- Frame R3, IP55
- Frame R4, IP21
- Frame R4, IP55
- Frame R5, IP21
- Frame R5, IP55
- Frame R6, IP21
- Frame R6, IP55
- Frame R7, IP21
- Frame R7, IP55
- Frame R8, IP21
- Frame R8, IP55
- Frame R9, IP21
- Frame R9, IP55
- Resistor braking, frames R0...R3
- Mechanical installation
- Start-up
- What this chapter contains
- Compliance with the European Machinery Directive
- Connection principle
- Wiring examples
- Cable types and lengths
- Start-up including acceptance test
- Acceptance test procedure
- Maintenance
- Safety data
- Abbreviations
- Electrical installation
- Diagnostics
- Technical data
- Safety instructions
- Product and service inquiries
|
142 Technical data gG fusesCheck on the fuse time-current curve to ensure the operating time of the fuse isbelow 0.5 seconds. Obey the local regulations.TypeACS580-01-Min. short-circuitcurrent1)InputcurrentgG (IEC 60269)NominalcurrentI2 t VoltageratingABB type IEC 60269sizeA A A A 2 s V3-phase UN = 400 or 480 V (380…415 V, 440…480 V)02A6-4 32 2.6 4 55 500 OFAF000H4 00003A3-4 48 3.3 6 110 500 OFAF000H6 00004A0-4 48 4.0 6 110 500 OFAF000H6 00005A6-4 80 5.6 10 360 500 OFAF000H10 00007A2-4 80 7.2 10 360 500 OFAF000H10 00009A4-4 128 9.4 16 740 500 OFAF000H16 00012A6-4 128 12.6 16 740 500 OFAF000H16 000017A-4 200 17.0 25 2500 500 OFAF000H25 000025A-4 256 25.0 32 4000 500 OFAF000H32 000032A-4 320 32.0 40 7700 500 OFAF000H40 000038A-4 400 38.0 50 16000 500 OFAF000H50 000045A-4 500 45.0 63 20100 500 OFAF000H63 000062A-4 800 62 80 37500 500 OFAF000H80 000073A-4 1000 73 100 37500 500 OFAF000H100 000061A-4 800 61 80 37500 500 OFAF000H80 000072A-4 1000 72 100 65000 500 OFAF000H100 000087A-4 1000 87 100 65000 500 OFAF000H100 000105A-4 1300 105 125 103000 500 OFAF00H125 1145A-4 1700 145 160 185000 500 OFAF00H160 1169A-4 3300 169 250 600000 500 OFAF0H250 1206A-4 5500 206 315 710000 500 OFAF1H315 1246A-4 6400 246 355 920000 500 OFAF1H355 2293A-4 7800 293 425 1300000 500 OFAF2H425 2363A-4 9400 363 500 2000000 500 OFAF2H500 2430A-4 10200 430 630 2800000 500 OFAF3H630 23AXD00000586715.xls G1) Minimum short-circuit current of the installation