Contents - List of related manuals
- 1. Safety instructions
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Contents of this chapter
- General safety in installation, start-up and maintenance
- Electrical safety in installation, start-up and maintenance
- Additional instructions and notes
- Grounding
- General safety in operation
- Contents of this manual
- Categorization by frame (size)
- Quick installation and commissioning flowchart
- Operation principle
- Layout
- Overview of power and control connections
- External control connection terminals, frames R0...R4
- External control connection terminals, frame R5...R9
- Control panel
- Type designation label
- Locations of the labels on the drive
- Type designation key
- Checking the installation site
- Required tools
- Moving the drive
- Unpacking and examining delivery, frame R5
- Frame R5 cable box (IP21, UL Type 1)
- Unpacking and examining delivery, frames R6...R9
- Frame R6 cable box (IP21, UL Type 1)
- Frame R7 cable box (IP21, UL Type 1)
- Frame R8 cable box (IP21, UL Type 1)
- Frame R9 cable box (IP21, UL Type 1)
- Installing the drive
- Installing the drive vertically side by side
- Other regions
- Typical power cable sizes
- Alternative power cable types
- Motor cable shield
- Selecting the control cables
- Relay cable
- Routing the cables
- Separate control cable ducts
- Implementing thermal overload and short-circuit protection
- Protecting the drive against ground faults
- Using a contactor between the drive and the motor
- Example bypass connection
- Protecting the contacts of relay outputs
- Limiting relay output maximum voltages at high installation altitudes
- Checking the insulation of the assembly
- Brake resistor assembly for R0...R3
- Ground-to-phase varistor
- Frames R0...R3
- Frames R4...R9
- Connecting the power cables
- Connection procedure, frames R0...R4
- Connection procedure, frame R5
- Connection procedure, frames R6...R9
- Motor cable
- DC connection
- Connecting the control cables
- Default I/O connection diagram (ABB standard macro)
- Control cable connection procedure R0...R9
- Installing option modules
- Wiring the modules
- Reinstalling covers
- Reinstalling covers, frame R5
- Reinstalling side plates and covers, frames R6...R9
- Connecting a PC
- Preventive maintenance intervals
- Heatsink
- Fans
- Replacing the cooling fan, frame R5
- Replacing the main cooling fans, frame R9
- Replacing the auxiliary cooling fan, frames R4...R9
- Capacitors
- LEDs
- Control panel LEDs
- Ratings
- NEMA ratings
- Sizing
- Ambient temperature derating, IP21
- Ambient temperature derating, IP55
- IP55 (UL Type 12) drive type -363A-4
- Switching frequency derating
- Fuses (IEC)
- gG fuses
- Dimensions, weights and free space requirements
- Cooling data and noise
- Terminal and lead-through data for the power cables
- Terminal and lead-through data for the control cables
- Electrical power network specification
- Brake resistor connection data for frames R0...R3
- Efficiency
- Materials
- CE marking
- Compliance with the EN 61800-3:2004 + A1:2012
- Category C2
- Category C4
- UL checklist
- Frame R0, IP21
- Frame R0, IP55
- Frame R1, IP21
- Frame R1, IP55
- Frame R2, IP21
- Frame R2, IP55
- Frame R3, IP21
- Frame R3, IP55
- Frame R4, IP21
- Frame R4, IP55
- Frame R5, IP21
- Frame R5, IP55
- Frame R6, IP21
- Frame R6, IP55
- Frame R7, IP21
- Frame R7, IP55
- Frame R8, IP21
- Frame R8, IP55
- Frame R9, IP21
- Frame R9, IP55
- Resistor braking, frames R0...R3
- Mechanical installation
- Start-up
- What this chapter contains
- Compliance with the European Machinery Directive
- Connection principle
- Wiring examples
- Cable types and lengths
- Start-up including acceptance test
- Acceptance test procedure
- Maintenance
- Safety data
- Abbreviations
- Electrical installation
- Diagnostics
- Technical data
- Safety instructions
- Product and service inquiries
|
208 Safe torque off function Abbreviations Declaration of conformityDeclaration of conformity (3AXD10000302783) is available on the Internet. Seesection Document library on the Internet on the inside of the back cover. CertificateTÜV certificate (3AXD10000302787) is available on the Internet. See sectionDocument library on the Internet on the inside of the back cover.Abbr. Reference DescriptionCCF EN ISO 13849-1 Common cause failure (%)DC EN ISO 13849-1 Diagnostic coverageFIT IEC 61508 Failure in time: 1E-9 hoursHFT IEC 61508 Hardware fault toleranceMTTFd EN ISO 13849-1 Mean time to dangerous failure: (The total number of lifeunits) / (the number of dangerous, undetected failures)during a particular measurement interval under statedconditionsPFD IEC 61508 Probability of failure on demandPFH D IEC 61508 Probability of dangerous failures per hourPL EN ISO 13849-1 Performance level. Levels a…e correspond to SILSC IEC 61508 Systematic capabilitySFF IEC 61508 Safe failure fraction (%)SIL IEC 61508 Safety integrity level (1…3)SILCL EN 62061 Maximum SIL (level 1…3) that can be claimed for a safetyfunction or subsystemSTO IEC/EN 61800-5-2 Safe torque offT1 IEC 61508 Proof test interval
PreviousNext |